Wishlist Endress+Hauser Endress+Hauser Vibronic Point level detection Liquiphant FTL51C Process temperature-50 °C...+150 °C(-58 °F...+302 °F)up to 230 °C / 450°F on requestProcess pressure / max. overpressure limitVacuum...40 bar(Vacuum...580 psi)Min. density of medium0.5g/cm³ (0.4g/cm³... Add to Wishlist
Wishlist Endress+Hauser Endress+Hauser Vibronic Point level detection Liquiphant FTL51H Process temperature-50 °C...+150 °C(-58 °F...+302 °F)Process pressure / max. overpressure limitVacuum...64 bar(Vacuum...928 psi)Min. density of medium0.5g/cm³(0.4g/cm³ optional)Measuring... Add to Wishlist
Wishlist Endress+Hauser Endress+Hauser Vibronic Point level detection Liquiphant FTL70 Process temperature-60 °C...+280 °C(-76 °F...+540 °F,(300°C / 572 °F 50h, cumulatedProcess pressure / max. overpressure limitVacuum...100 bar(Vacuum...1450 psi)Measuring principleVibration... Add to Wishlist
Wishlist Endress+Hauser Endress+Hauser Vibronic Point level detection Liquiphant FTL80 Process temperature-60°C...+280°C(-76°F...+540°F)Process pressure / max. overpressure limitVacuum...100 bar(1450 psi)Min. density of mediumDensity from 0.4 g/cm3(0.4 SGU)Measuring principleVibration... Add to Wishlist
Wishlist Endress+Hauser Endress+Hauser Vibronic Point level detection Liquiphant FTL81 Process temperature-60°C...+280°C(-76°F...+540°F)Process pressure / max. overpressure limitVacuum...100 bar(1450 psi)Min. density of mediumDensity from 0.4 g/cm3(0.4 SGU)Measuring principleVibration... Add to Wishlist
Wishlist Endress+Hauser Endress+Hauser Vibronic Point level detection Liquiphant FTL85 Process temperature–50°C...+150°C(–58°F...+300°F)Process pressure / max. overpressure limitVacuum...40 bar(580 psi)Min. density of mediumDensity from 0.4 g/cm3(0.4 SGU)Measuring principleVibration... Add to Wishlist
Wishlist Endress+Hauser Endress+Hauser Vibronic Point level detection Nivotester FailSafe FTL825 Measuring principleVibration LiquidsCharacteristic / ApplicationFailSafe level transmitter point level.Top hat rail mountingConnection to FTL80/81/85Permanent self-monitoring,LIVE-Signal... Add to Wishlist
Wishlist Endress+Hauser Endress+Hauser Vibronic Point level detection Nivotester FTL325N Measuring principleVibration LiquidsCharacteristic / ApplicationSwitching unit NAMUR technology for rail mountingSIL2, according 61511Intrinsically safeSupply / CommunicationNAMUR24V AC,DC / 230V... Add to Wishlist
Wishlist Endress+Hauser Endress+Hauser Vibronic Point level detection Nivotester FTL325P Measuring principleVibration LiquidsCharacteristic / ApplicationSwitching unit PFM technology for rail mountingIntrinsically safeHighest SIL safetySpecialitiesIf sensors are redundant, SIL3Supply /... Add to Wishlist
Wishlist Endress+Hauser Endress+Hauser Vibronic Point level detection Soliphant FTM20 Process temperature-40°C ... 150°C(-40°F ... 300°F)Process pressure / max. overpressure limitVacuum ... 25 bar(Vacuum ... 360 psi)Min. density of medium200 g/lMeasuring principleVibration... Add to Wishlist
Wishlist Endress+Hauser Endress+Hauser Vibronic Point level detection Soliphant FTM21 Process temperature-40°C ... 150°C(-40°F ... 300°F)Process pressure / max. overpressure limitVacuum ... 25 bar(Vacuum ... 360 psi)Min. density of medium200 g/lMeasuring principleVibration... Add to Wishlist
Wishlist Endress+Hauser Endress+Hauser Vibronic Point level detection Soliphant FTM50 Process temperature-50°C ... 280°C(-60°F ... 540°F)Process pressure / max. overpressure limitVacuum ... 25 bar(Vacuum ... 360 psi)Min. density of mediumStandard fork: 10 g/lShort fork: 50... Add to Wishlist
Wishlist Endress+Hauser Endress+Hauser Vibronic Point level detection Soliphant FTM51 Process temperature-50°C ... 280°C(-60 °F ... 540°F)Process pressure / max. overpressure limitVacuum ... 25 bar(Vacuum ... 360 psi)Min. density of mediumStandard fork: 10 g/lShort fork: 50... Add to Wishlist
Wishlist Endress+Hauser Endress+Hauser Vibronic Point level detection Soliphant FTM52 Process temperature-40°C ...80 °C(-40°F ... 170°F)Process pressure / max. overpressure limitVacuum ... 2 bar(Vacuum ... 30 psi)max. 6 bar / 80 psi for EExd/EExdeMin. density of mediumStandard fork:... Add to Wishlist
Wishlist Endress+Hauser Endress+Hauser Vibronic Point level switch Liquiphant FTL71 Process temperature-60 °C...+280 °C(-76 °F...+540 °F)(300°C / 572°F, 50h cumulated)Process pressure / max. overpressure limitVacuum...100 bar(Vacuum...1450 bar)Min. density of medium0.5g/cm³ (0... Add to Wishlist
Wishlist Endress+Hauser Endress+Hauser Water hardness analyzer Liquiline System CA80HA Measurement range0 to 80 mg/l CaCO30 to 80 mg/l with dilution function to maximum 16 to 1600 mg/l CaCO3Process temperature4 to 40 °C (39 to 104 °F)Process pressureUnpressurizedMeasuring... Add to Wishlist