Wishlist Endress+Hauser Endress+Hauser MLTTS01 Modular thermometer with RTD or TC insert AccuracyRTD Class A acc. to IEC 60751TC class 1 acc. To EN 60584Response timedepending on configurationMax. process pressure (static)depending on configurationOperating temperature rangePT100:-50…500 °C(-58...932 °F)TC:max. 600 °C(max. 1.112 °F)Max... Add to Wishlist
Wishlist Endress+Hauser Endress+Hauser MLTTS00 Modular thermometer with RTD or TC insert AccuracyRTD Class A acc. to IEC 60751TC class 1 acc. To EN 60584Response timedepending on configurationMax. process pressure (static)depending on ThermowellOperating temperature rangePT100:-50…500 °C(-58...932 °F)TC:max. 1.100 °C(max. 2.012 °F)Max... Add to Wishlist
Wishlist Endress+Hauser Endress+Hauser TWF16 Protection tube for high temperature assemblies Max. process pressure (static)1 bar (15 psi)Maximum standard immersion length2.200 mm (86,61")Max. immersion length on request4.525 mm (178,15")Measuring principleFabricated ThermowellCharacteristic / Applicationmetric styleFabricated from segmentswelded... Add to Wishlist
Wishlist Endress+Hauser Endress+Hauser TWF11 Protection tube for high temperature assemblies Max. process pressure (static)1 bar (15 psi)Maximum standard immersion length1.500 mm (59,06")Max. immersion length on request4.000 mm (157,48")Measuring principleFabricated ThermowellCharacteristic / Applicationmetric styleFabricated from... Add to Wishlist
Wishlist Endress+Hauser Endress+Hauser TW15 Barstock thermowell Max. process pressure (static)400 bar (5802 psi)Maximum standard immersion length250 mm (9,84")Max. immersion length on request400 mm (15,75")Measuring principleBar stock ThermowellCharacteristic / Applicationmetric styleDIN 43772 Form 4/4Fflanged... Add to Wishlist
Wishlist Endress+Hauser Endress+Hauser TU54 Flanged barstock thermowell, US style Max. process pressure (static)500 bar (7252 psi)Maximum standard immersion length24"Measuring principleBar stock ThermowellCharacteristic / ApplicationUS-styleflanged process connectionsHead connectioninternal thread:1/2" NPTMaximum standard immersion... Add to Wishlist
Wishlist Endress+Hauser Endress+Hauser TU53 Threaded barstock thermowell, US style Max. process pressure (static)500 bar (7252 psi)Maximum standard immersion length24"Max. immersion length on requestNot definedMeasuring principleBar stock ThermowellCharacteristic / ApplicationUS-stylethreaded process connectionsHead connectioninternal... Add to Wishlist
Wishlist Endress+Hauser Endress+Hauser TU52 Socket weld barstock thermowell, US style Max. process pressure (static)500 bar (7252 psi)Maximum standard immersion length24"Measuring principleBar stock ThermowellCharacteristic / ApplicationUS-styleweld-in process connectionsHead connectioninternal thread:1/2" NPTMaximum standard immersion... Add to Wishlist
Wishlist Endress+Hauser Endress+Hauser TU51 Weld-in barstock thermowell, US style Max. process pressure (static)500 bar (7252 psi)Maximum standard immersion length24"Measuring principleBar stock ThermowellCharacteristic / ApplicationUS-styleweld-in process connectionsHead connectioninternal thread:1/2" NPTMaximum standard immersion... Add to Wishlist
Wishlist Endress+Hauser Endress+Hauser Thermophant T TTR35 Temperature switch Accuracy-50...75 °C: <0,5 K(-58...167 °F: <0,9 °F)75...150 °C: <0,65 K(167...302 °F: <1,2 °F)Operating temperature range-50...150 °C (-58...302 °F)Measuring principleTemperature switchCharacteristic / ApplicationIntelligent temperature switch... Add to Wishlist
Wishlist Endress+Hauser Endress+Hauser Thermophant T TTR31 Temperature switch Accuracy-50...75 °C: <0,5 K(-58...167 °F: <0,9 °F)75...150 °C: <0,65 K(167...302 °F: <1,2 °F)Operating temperature range-50...150 °C (-58...302 °F)Measuring principleTemperature switchCharacteristic / ApplicationIntelligent temperature switch... Add to Wishlist
Wishlist Endress+Hauser Endress+Hauser iTEMP TMT80 Temperature head transmitter Accuracy(Pt100, -50...250 °C) <= 0,5 K(Pt100, -58...482 °F) <= 0,9 °FMeasuring principleHead transmitterInput1 x RTD, TCOutput1 x analog 4...20 mAAuxiliary power supply8...35 V DCCommunicationpc-programmableInstallationTerminal head form... Add to Wishlist
Wishlist Endress+Hauser Endress+Hauser iTEMP TMT188 Temperature head transmitter Accuracy(Type K) <= 0,5 K(Type K) <= 0,9 °FMeasuring principleHead transmitterInput1 x TCOutput1 x analog 4...20 mAAuxiliary power supply8...35 V DC (standard-version)8...30 V DC (Ex-version)InstallationTerminal head form BAccuracy(Type K) <=... Add to Wishlist
Wishlist Endress+Hauser Endress+Hauser iTEMP TMT128 DIN rail temperature transmitter Accuracy(Type K) <= 0,5 K(Type K) <=0,9 °FMeasuring principleRail transmitterInput1 x TCOutput1 x analog 4...20 mAAuxiliary power supply12...35 V DC (standard-version)12...30 V DC (Ex-version)InstallationDIN-railAccuracy(Type K) <= 0,5 K(Type K)... Add to Wishlist
Wishlist Endress+Hauser Endress+Hauser iTEMP TMT127 DIN rail temperature transmitter Accuracy(Pt100, -50...200 °C) <= 0,2 K(Pt100, -58...392 °F) <= 0,4 °FMeasuring principleRail transmitterInput1 x analog RTD (Pt100)Output1 x analog 4...20 mAAuxiliary power supply12...35 V DC (standard-version)12...30 V DC... Add to Wishlist
Wishlist Endress+Hauser Endress+Hauser TH56 US style thermocouple sensor, with plug connection AccuracyStandard acc. to ASTM E-230Special acc. to ASTM E-230Response time63% rt = 0,3 sMax. process pressure (static)Standard acc. to ASTM E-230Special acc. to ASTM E-230Operating temperature rangeType T:-270 °C ...370 °C(-454 °F ...698 °F)Type J:-210... Add to Wishlist