Wishlist Endress+Hauser Endress+Hauser Capacitance Level measurement Liquicap FMI21 Accuracy< 1%Process temperature-40 °C ... 100 °C(-40 °F ... 212 °F)Process pressure / max. overpressure limitVacuum ... 10 bar(Vacuum ... 145 psi)Max. measurement distance2.5 m (8 ft)Main wetted partsProbe rods:316L/1.4404 / PPOption: carbon fibre PP... Add to Wishlist
Wishlist Endress+Hauser Endress+Hauser Radiometric measurement Gamma Modulator FHG65 Measuring principleRadiometricCharacteristic / ApplicationRadiometric MeasurementEffective Suppression of Background Radiation and ExtraneousRadiation at the Gammapilot FMG60SpecialitiesUnhindered measurement with Gammapilot MFMG60 in the event... Add to Wishlist
Wishlist Endress+Hauser Endress+Hauser Servo tank gauging instrument Proservo NMS81 Accuracyup to 0.4 mmProcess temperature-200°C...200°C(-328°F...392°F)Process pressure / max. overpressure limitup to 25 bar (363 psi) absMax. measurement distance47 m (154 ft)Main wetted parts316L, AlloyC276, PTFEMeasuring principleServo / Float ... Add to Wishlist
Wishlist Endress+Hauser Endress+Hauser Servo tank gauging instrument Proservo NMS80 Accuracyup to 0.4 mmProcess temperature-200°C...200°C(-328°F...392°F)Process pressure / max. overpressure limit0,2...6 bar absMax. measurement distance36 m (118 ft)Main wetted parts316L, AlloyC276, PTFEMeasuring principleServo / Float Tank... Add to Wishlist
Wishlist Endress+Hauser Endress+Hauser Conductive Point level detection Liquipoint FTW32 Process temperature-40 °C ... 70 °C(-40 °F ... 158 °F)Process pressure / max. overpressure limitVacuum ... 10 bar(Vacuum ... 145 psi)Min. conductivity of medium10 µS/cmMeasuring principleConductiveCharacteristic / ApplicationCompact rope probe with multi... Add to Wishlist
Wishlist Endress+Hauser Endress+Hauser Conductive Point level detection Liquipoint FTW31 Process temperature-40 °C ... 100 °C(-40 °F ... 212 °F)Process pressure / max. overpressure limitVacuum ... 10 bar(Vacuum ... 145 psi)Min. conductivity of medium10 µS/cmMeasuring principleConductiveCharacteristic / ApplicationCompact rod probe with... Add to Wishlist
Wishlist Endress+Hauser Endress+Hauser Vibronic Point level detection Soliphant FTM21 Process temperature-40°C ... 150°C(-40°F ... 300°F)Process pressure / max. overpressure limitVacuum ... 25 bar(Vacuum ... 360 psi)Min. density of medium200 g/lMeasuring principleVibration SolidsCharacteristic / ApplicationPoint level switch for fine... Add to Wishlist
Wishlist Endress+Hauser Endress+Hauser Vibronic Point level detection Soliphant FTM20 Process temperature-40°C ... 150°C(-40°F ... 300°F)Process pressure / max. overpressure limitVacuum ... 25 bar(Vacuum ... 360 psi)Min. density of medium200 g/lMeasuring principleVibration SolidsCharacteristic / ApplicationCompact point level switch for... Add to Wishlist
Wishlist Endress+Hauser Endress+Hauser Vibronic Point level detection Liquiphant FTL50 Process temperature-50 °C...+150 °C(-58 °F...+302 °F)Process pressure / max. overpressure limitVacuum...64 bar(Vacuum...928 psi)Min. density of medium0.5g/cm³(0.4g/cm³ option)Measuring principleVibration LiquidsCharacteristic / ApplicationModular housing... Add to Wishlist
Wishlist Endress+Hauser Endress+Hauser Liquiphant FTL41 Process temperature-40 °C...+150 °C(-40 °F...+302 °F)Process pressure / max. overpressure limitVacuum...40 bar(Vacuum...580 psi)Min. density of medium0.5 g/cm³(0.4 g/cm³ optional)Measuring principleVibration LiquidsCharacteristic / ApplicationCompact... Add to Wishlist
Wishlist Endress+Hauser Endress+Hauser Capacitance Point level detection Solicap FTI77 Process temperature-50°C ... 400°C(-58°F ... 752°F)Process pressure / max. overpressure limitVacuum ... 10 bar(Vacuum ... 145 psi)Measuring principleCapacitive SolidCharacteristic / ApplicationPartly isolated sword probe / rope probe for very high... Add to Wishlist
Wishlist Endress+Hauser Endress+Hauser Capacitance Point level detection Solicap FTI56 Process temperature-50°C ... 180°C(-58°F ... 356°F)Process pressure / max. overpressure limitVacuum ... 25 bar(Vacuum ... 362 psi)Measuring principleCapacitive SolidCharacteristic / ApplicationFully / partly isulated rope probe for small-grain /... Add to Wishlist
Wishlist Endress+Hauser Endress+Hauser Capacitance Point level detection Solicap FTI55 Process temperature-50°C ... 180°C(-58°F ... 356°F)Process pressure / max. overpressure limitVacuum ... 25 bar(Vacuum ... 362 psi)Measuring principleCapacitive SolidCharacteristic / ApplicationFully / partly isulated rod probe for small-grain /... Add to Wishlist
Wishlist Endress+Hauser Endress+Hauser Capacitance Point level detection Liquicap FTI52 Process temperature-80 °C ... +200 °C(-112 °F ... +392 °F)Process pressure / max. overpressure limitVacuum ... 100 bar(Vacuum ... 1450 psi)Measuring principleCapacitive LiquidCharacteristic / ApplicationCapacitive Rope probeSpecialitiesInterface... Add to Wishlist
Wishlist Endress+Hauser Endress+Hauser Capacitance Point level detection Liquicap FTI51 Process temperature-80 °C ... +200 °C(-112 °F ... +392 °F)Process pressure / max. overpressure limitVacuum ... 100 bar(Vacuum ... 1450 psi)Measuring principleCapacitive LiquidCharacteristic / ApplicationCapacitive rod probeSpecialitiesInterface... Add to Wishlist
Wishlist Endress+Hauser Endress+Hauser Radiometric Point level detection Gammapilot FTG20 Process temperatureAnyProcess pressure / max. overpressure limitAnyMin. density of mediumAnyMin. conductivity of mediumAnyMeasuring principleRadiometric LimitCharacteristic / ApplicationRadiometric Transmitter with 1 to 3 Geiger-Müller counters for... Add to Wishlist