Wishlist Endress+Hauser Endress+Hauser Analog free chlorine sensor CCS51 Measurement rangeTrace: 0 to 5 mg/l HOClStandard: 0 to 20 mg/l HOClProcess temperature+0 to 55 °C (32 to 130°F), non-freezingProcess pressure1 bar (14.5 psi)Measuring method- Closed, membrane covered... Add to Wishlist
Wishlist Endress+Hauser Endress+Hauser Analog ORP sensor Ceragel CPS72 Measurement range-1500 mV - +1500 mVProcess temperature-15°C - 135°CProcess pressuremax. 16barMeasuring principleSensor ORP / RedoxApplication- Hygienic and sterile applications - pharmaceuticals,... Add to Wishlist
Wishlist Endress+Hauser Endress+Hauser Analog ORP sensor Ceraliquid CPS42 Measurement range-1500 mV - +1500 mVProcess temperature-15°C - 130°CProcess pressuremax. 8barMeasuring principleSensor ORP / RedoxApplication- Special applications with high requirements with regard... Add to Wishlist
Wishlist Endress+Hauser Endress+Hauser Analog ORP sensor Orbipac CPF82 Measurement range-1500mV - -1500mVProcess temperature-10°C - 110°C(14°F - 230°F)Process pressuremax. 10 bar(145 psi)Measuring principleSensor ORP / RedoxApplicationWater, waste water, process,... Add to Wishlist
Wishlist Endress+Hauser Endress+Hauser Analog ORP sensor Orbisint CPS12 Measurement range-1500 mV to +1500 mVProcess temperaturemax. 135°C (274°F)Process pressuremax. 16bar (230psi)Measuring principleSensor ORP / RedoxApplicationStandard applications in process and... Add to Wishlist
Wishlist Endress+Hauser Endress+Hauser Analog pH sensor Ceragel CPS71 Measurement rangepH 0-14Process temperature-15°C ... 140°C(5°F - 284°F)Process pressuremax. 13 bar(188 psi)Measuring principlePotentiometricApplicationHygienic and sterile applications,... Add to Wishlist
Wishlist Endress+Hauser Endress+Hauser Analog pH sensor Ceraliquid CPS41 Measurement rangepH 0-14Process temperaturemax. 135°C (274°F)Process pressuremax. 10bar (145psi)Measuring principlePotentiometricApplication- special applications with high requirements with regard... Add to Wishlist
Wishlist Endress+Hauser Endress+Hauser Analog pH sensor Ceratex CPS31 Measurement rangepH 1 - 12Process temperature0 - 80 C (32 - 176 F)Process pressure1 - 4 bar abs (15 - 60 psi)Measuring principlePotentiometricApplicationDrinking water and swimming pool water, pH... Add to Wishlist
Wishlist Endress+Hauser Endress+Hauser Analog pH sensor Orbipac CPF81 Measurement rangepH 0-14Process temperature-10°C - 110°C(14°F - 230°F)Process pressuremax. 10 bar(145 psi)Measuring principlePotentiometricApplicationWater, waste water, process,... Add to Wishlist
Wishlist Endress+Hauser Endress+Hauser Analog pH sensor Orbipore CPS91 Measurement rangepH 0-14Process temperaturemax. 110°C(230°F)Process pressuremax. 10 bar(145 psi)Measuring principlePotentiometricApplication- Process applications - media with high contamination:... Add to Wishlist
Wishlist Endress+Hauser Endress+Hauser Analog pH sensor Orbisint CPS11 Measurement rangepH 0-14Process temperaturemax. 135°C (274°F)Process pressuremax. 16 bar (230 psi)Measuring principlePotentiometricApplicationStandard applications in process and the environment... Add to Wishlist
Wishlist Endress+Hauser Endress+Hauser Analog pH sensor Purisys CPF201 Measurement rangepH 1-13 (<100µS/cm)Process temperature2°C - 75°C(36°F - 167°F)Process pressuremax. 3 bar(43.5 psi)Measuring principlePotentiometricApplicationUltra pure water (<100µS/cm);... Add to Wishlist
Wishlist Endress+Hauser Endress+Hauser Analog total chlorine sensor CCS120 Measurement range0,1 - 10ppm total chlorine; pH 6,5 - 9,5Process temperature5°C - 45°CProcess pressure0bar - 3barMeasuring principleTotal chlorineApplicationPotable water,Process water, Waste water,... Add to Wishlist
Wishlist Endress+Hauser Endress+Hauser Assembly for process photometers OUA260 Process temperature0 to 130 °C (32 to 194 °F)Process pressureup to 20 bar (300 psi) depending on material, mean diameter and process connectionMeasuring principleUV absorbanceApplicationFlow assembly... Add to Wishlist
Wishlist Endress+Hauser Endress+Hauser Asset Health Monitoring Solution SAH70 The Asset Health Monitor quickly gives an overview of the plant device status. Add to Wishlist
Wishlist Endress+Hauser Endress+Hauser Automatic water sampler for North America Liquistation CSF34 FunctionsStationary samplerSuction height8m (26.25ft)CabinetPlastic ASA+PCProcess temperatureSample temperature 2 to 50°C (36 to 122°F)Process pressuremax 0,8bar ( 11.6PSI)Measuring... Add to Wishlist