Wishlist Endress+Hauser Endress+Hauser Digital ORP sensor Ceraliquid CPS42D Measurement range-1500 mV - +1500 mVProcess temperature-15°C - 130°CProcess pressuremax. 8barMeasuring principleSensor ORP / RedoxApplication- Special applications with high requirements with regard... Add to Wishlist
Wishlist Endress+Hauser Endress+Hauser Digital ORP sensor Memosens CPF82E Measurement range-1500mV to +1500mVProcess temperature0 to 80 °C (32 to 170 °F)Process pressure1 to 10 bar abs at 80 °C(15 to 145 psi abs at 176 °F)Measuring principleSensor ORP /... Add to Wishlist
Wishlist Endress+Hauser Endress+Hauser Digital ORP sensor Memosens CPS12E Measurement range-1500 mV to +1500 mVProcess temperature-15 to 135 °C(5 to 275 °F)Process pressure0.8 to 17 bar (11.6 to 246.5 psi) absoluteMeasuring principleSensor ORP / RedoxApplicationLong-term... Add to Wishlist
Wishlist Endress+Hauser Endress+Hauser Digital ORP sensor Memosens CPS42E Measurement range–1 500 to 1 500 mVProcess temperature–15 to 135 °C (5 to 275 °F)Process pressure0.8 to 11 bar (11.6 to 159.5 psi) (absolute)Measuring principleSensor ORP / RedoxApplicationMedia with... Add to Wishlist
Wishlist Endress+Hauser Endress+Hauser Digital ORP sensor Memosens CPS62E Measurement range–1 500 to 1 500 mVProcess temperature0 to 100 °C (32 to 212 °F)0 to 140 °C (32 to 284 °F) (140 °C (284 °F) or sterilization only)Process pressure0.8 to 7 bar (11.6 to 101.5 psi)... Add to Wishlist
Wishlist Endress+Hauser Endress+Hauser Digital ORP sensor Memosens CPS72E Measurement range–1 500 to 1 500 mVProcess temperature0 to 140 °C (32 to 284 °F)Process pressure0.8 to 14 bar (11.6 to 203 psi) (absolute)Measuring principleSensor ORP / RedoxApplicationProcess... Add to Wishlist
Wishlist Endress+Hauser Endress+Hauser Digital ORP sensor Memosens CPS92E Measurement range–1 500 to 1 500 mVProcess temperature0 to 110 °C (32 to 230 °F)Process pressure0.8 to 14 bar (11.6 to 203 psi) (absolute)Measuring principleSensor ORP / RedoxApplication• Chemical... Add to Wishlist
Wishlist Endress+Hauser Endress+Hauser Digital ORP sensor Orbipac CPF82D Measurement range-1500mV to +1500mVProcess temperature0 to 80 °C (32 to 170 °F)Process pressure1 to 10 bar abs at 80 °C(15 to 145 psi abs at 176 °F)Measuring principleSensor ORP /... Add to Wishlist
Wishlist Endress+Hauser Endress+Hauser Digital ORP sensor Orbipore CPS92D Measurement range-1500 mV - +1500 mVProcess temperaturemax. 110°C (230°F)Process pressuremax. 13bar (189psi)Measuring principleSensor ORP / RedoxApplicationProcessapplications, heavy soiled media,... Add to Wishlist
Wishlist Endress+Hauser Endress+Hauser Digital ORP sensor Orbisint CPS12D Measurement range-1500 mV to +1500 mVProcess temperature-15 to 135 °C(5 to 275 °F)Process pressure0 to 16 bar(0 to 232 psi)Measuring principleSensor ORP / RedoxApplicationStandard applications in... Add to Wishlist
Wishlist Endress+Hauser Endress+Hauser Digital oxygen sensor Memosens COL37E Measurement range0 to 200 %SATProcess temperature–5 to +60 ˚C (23 to 140 ˚F)Process pressure1 bar, not intended for continues measurment in processMeasuring principleOptical oxygen... Add to Wishlist
Wishlist Endress+Hauser Endress+Hauser Digital oxygen sensor Memosens COS22E Measurement rangeStandard sensor: 0 to 60 mg/l, 0 to 600 %SAT, 0 to 1200 hPa, 0 to 100 Vol%Trace sensor: 0 to 10 mg/l, 0 to 120 %SAT, 0 to 250 hPa, 0 to 25 Vol%Process temperature-5 to 135 °C (23 to... Add to Wishlist
Wishlist Endress+Hauser Endress+Hauser Digital oxygen sensor Memosens COS51E Measurement range0.01 to 100 mg/l0.00 to 1000 %SAT0 to 2000 hPaProcess temperature-5 to 60 °C(20 to 140 °F)Process pressureMax. 5 bar abs(Max. 72.5 psi abs)Measuring principleAmperometric oxygen... Add to Wishlist
Wishlist Endress+Hauser Endress+Hauser Digital oxygen sensor Oxymax COS61D Measurement range0 to 20 mg/l0 to 200 %SAT0 to 400 hPaProcess temperature-5 to 60 °C(20 to 140 °F)Process pressureMax. 10 bar abs(Max. 145 psi)Measuring principleOptical oxygen... Add to Wishlist
Wishlist Endress+Hauser Endress+Hauser Digital ozone sensor Memosens CCS58D Measurement range0 to 2 mg/lProcess temperature+0 to 45 °C (32 to 110 °F), non freezingProcess pressure1 bar (14.5 psi), 2 bar (29 psi) absoluteMeasuring method- closed 2 electrode system- conversion... Add to Wishlist
Wishlist Endress+Hauser Endress+Hauser Digital ozone sensor Memosens CCS58E Measurement range0 to 2 mg/lProcess temperature+0 to 45 °C (32 to 110 °F), non freezingProcess pressure1 bar (14.5 psi), 2 bar (29 psi) absoluteMeasuring method- closed 2 electrode system- conversion... Add to Wishlist