Wishlist Endress+Hauser Endress+Hauser Differential pressure Deltabar PMD55 Accuracy0,1%"PLATINUM" 0,075%Max. measurement error0,1%"PLATINUM" 0,075%Process temperature-40 °C...85 °C(-40 °F...185 °F)Medium temperature rangeTemperature gradient from pressure pipingPressure... Add to Wishlist
Wishlist Endress+Hauser Endress+Hauser Differential pressure Deltabar PMD75 AccuracyStandard: 0.05%Platinum: up to 0.035%Max. measurement error0,075%"PLATINUM" 0,05%Process temperature-40 °C...85 °C(-40 °F...185 °F)Medium temperature rangeTemperature gradient from pressure... Add to Wishlist
Wishlist Endress+Hauser Endress+Hauser Digital 4-electrode conductivity sensor Memosens CLS82E Measurement range1 µS/cm to 500 mS/cmProcess temperature-5 to 120 °C (23 to 248 °F)Sterilization: max. 140 °C at 6 bar for max. 45 min(Max. 284 °F at 87 psi for max. 45 min)Process pressure17 bar abs... Add to Wishlist
Wishlist Endress+Hauser Endress+Hauser Digital ammonium and nitrate sensor ISEmax CAS40D Measurement rangeAmmonium:0.1 to 1000 mg/l (NH4-N)Nitrate:0.1 to 1000 mg/l (NO3-N)Potassium:1 to 1000 mg/lChloride:1 to 1000 mg/lProcess temperature2 °C to 40°C (36 to 100 °F)Process pressure400 mbar... Add to Wishlist
Wishlist Endress+Hauser Endress+Hauser Digital chlorine dioxide sensor Memosens CCS50D Measurement rangeTrace: 0 to 5 mg/l ClO2Standard: 0 to 20 mg/l ClO2High: 0 to 200 mg/l ClO2Process temperature0 to 55 °C , non-freezing(32 to 130 °F)Process pressureMax. 2 bar abs(Max. 29 psi... Add to Wishlist
Wishlist Endress+Hauser Endress+Hauser Digital chlorine dioxide sensor Memosens CCS50E Measurement rangeTrace: 0 to 5 mg/l ClO2Standard: 0 to 20 mg/l ClO2High: 0 to 200 mg/l ClO2Process temperature0 to 55 °C , non-freezing(32 to 130 °F)Process pressureMax. 2 bar abs(Max. 29 psi... Add to Wishlist
Wishlist Endress+Hauser Endress+Hauser Digital combined pH/ORP sensor Memosens CPS16D Process temperature0 to 135 °C (32 to 275 °F)Process pressure1 to 17 bar (15 to 246 psi)Measuring principlePotentiometricApplicationStandard applications in process and environment, long-term... Add to Wishlist
Wishlist Endress+Hauser Endress+Hauser Digital combined pH/ORP sensor Memosens CPS16E Measurement rangeORP: –1 500 … 1 500 mVApplication: A• pH: 1 to 12Application B• pH: 0 to 14Process temperatureApplication A: –15 to 80 °C (5 to 176 °F)Application B: 0 to 135 °C (32 to 275... Add to Wishlist
Wishlist Endress+Hauser Endress+Hauser Digital combined pH/ORP sensor Memosens CPS76D Measurement rangepH 0-14Process temperature-15°C ... 140°C(5°F - 284°F)Process pressuremax. 13 bar(188 psi)depends on selected versionMeasuring principlePotentiometricApplicationHygienic and sterile... Add to Wishlist
Wishlist Endress+Hauser Endress+Hauser Digital combined pH/ORP sensor Memosens CPS96D Measurement rangepH 0-14Process temperaturemax. 110°C(230°F)Process pressuremax. 10 bar(145 psi)Measuring principlePotentiometricApplication- Process applications - media with high contamination:... Add to Wishlist
Wishlist Endress+Hauser Endress+Hauser Digital combined pH/ORP sensor Memosens CPS96E Measurement rangeORP: –1 500 to 1 500 mVpH: 0 to 14Process temperature0 to 110 °C (32 to 230 °F)Process pressure0.8 to 14 bar (11.6 to 203 psi) absoluteMeasuring principlePotentiometricApplicationpH... Add to Wishlist
Wishlist Endress+Hauser Endress+Hauser Digital conductivity sensor Condumax CLS16D Measurement rangek=0,1: 0,04 to 500 µS/cmProcess temperature-5 to 120 °C (23 to 248 °F)For Sterilizsation: max. 150 °C at 5 bar(Max. 302 °F at 73 psi)Process pressure13 bar at 20 °C (188 psi at 68... Add to Wishlist
Wishlist Endress+Hauser Endress+Hauser Digital conductivity sensor Indumax CLS50D Measurement range2µS/cm to 2000 mS/cmProcess temperaturePEEK: max. 125°C (max. 260 °F)PFA: max. 110°C (max. 230 °F)Process pressurePEEK: max. 21 bar (max. 304.5 psi)PFA: max. 17 bar (max. 246.5... Add to Wishlist
Wishlist Endress+Hauser Endress+Hauser Digital conductivity sensor Indumax CLS54D Measurement range100 µS/cm to 2000 mS/cmCell constant k: 6.3 1/cmProcess temperature-10 °C to 125 °C (14 °F to 257 °F)Sterilization: 150 °C at 6 bar abs for max. 60 min(302 °F at 87 psi abs for max... Add to Wishlist
Wishlist Endress+Hauser Endress+Hauser Digital conductivity sensor Memosens CLL47E Measurement range5 μS/cm to 200 mS/cmProcess temperature0 to 100 °C (32 to 212 °F)Process pressure1 bar, not intended for continuous measurement in processMeasuring... Add to Wishlist
Wishlist Endress+Hauser Endress+Hauser Digital conductivity sensor Memosens CLS15E Measurement rangek=0,01: 0.04 to 20 µS/cmk=0,1: 0.10 to 200 µS/cmProcess temperatureThreaded with fixed cable:-20 to 100 °C (-4 to 212 °F)Threaded with plug-in head:-20 to 120 °C (-4 to 248... Add to Wishlist