Endress+Hauser
Endress+Hauser Vibronic Point level detection Soliphant FTM50
REQUEST A QUOTE
Process temperature | -50°C ... 280°C (-60°F ... 540°F) |
---|---|
Process pressure / max. overpressure limit | Vacuum ... 25 bar (Vacuum ... 360 psi) |
Min. density of medium | Standard fork: 10 g/l Short fork: 50 g/l |
Measuring principle | Vibration Solids |
Characteristic / Application | Compact point level switch for fine grained solids and powder Grain size <= 10 mm (<= 0.39 in) Fork sensor No calibration required Not affected by build-up or external vibration Robust Switch value visible from outside |
Specialities | Build-up and corrosion detection Remote version 3 temperature versions available SIL 2 |
Supply / Communication | 10-55V DC PNP 3-wire 19-253V AC 2-wire 19...253V AC / 19V...55V DC 2 relay contact 8/16mA NAMUR PFM |
Ambient temperature | -50°C ... 70°C (-60°F ... 160 °F) |
Process temperature | -50°C ... 280°C (-60°F ... 540°F) |
Process pressure / max. overpressure limit | Vacuum ... 25 bar (Vacuum ... 360 psi) |
Min. density of medium | Standard fork: 10 g/l Short fork: 50 g/l |
Main wetted parts | selectable: 316L 3,2um 316L 0,8um 316L PTFE coated (to avoid build-up) 316L ETFE coated (to avoid corrosion) |
Process connection | Thread R 1 1/2" 1 1/4" NPT 1 1/2" NPT EN Flange DN50...DN100 ASME Flange 2"...4" JIS Flange 50A...100A |
Process connection hygienic | Tri-Clamp ISO2852 |
Sensor length | Standard: 200mm (8") Short: 145mm (5.7") |
Communication | DC PNP 2-wire AC Thyristor DPDT relay 8/16mA NAMUR PFM |
Certificates / Approvals | ATEX, FM, CSA, CSA C/US, IEC Ex, JPN, INMETRO, NEPSI, EAC |
Safety approvals | SIL |
Design approvals | EN 10204-3.1 |
Options | Glass cover Temperature spacer EN10204-3.1 |
Components | PFM: FTL325P, FTL375P NAMUR: FTL325N, FTL375N |
Returns Policy