Endress+Hauser
Endress+Hauser Vibronic Point level detection Soliphant FTM21
REQUEST A QUOTE
Process temperature | -40°C ... 150°C (-40°F ... 300°F) |
---|---|
Process pressure / max. overpressure limit | Vacuum ... 25 bar (Vacuum ... 360 psi) |
Min. density of medium | 200 g/l |
Measuring principle | Vibration Solids |
Characteristic / Application | Point level switch for fine grained solids Grain size <= 25 mm (<= 0.98 in) Single rod No calibration required Not affected by build-up or external vibration Robust Switch value visible from outside Tube extension |
Supply / Communication | 10 - 45 VDC 19 - 253 VAC relay DC PNP 10 - 45 V |
Ambient temperature | -40°C ... 70°C (-40°F ... 160°F) |
Process temperature | -40°C ... 150°C (-40°F ... 300°F) |
Process pressure / max. overpressure limit | Vacuum ... 25 bar (Vacuum ... 360 psi) |
Min. density of medium | 200 g/l |
Main wetted parts | 316L |
Process connection | Thread R 1" R 1 1/2" 1 1/4" NPT 1 1/2" NPT |
Sensor length | 500 mm (20") 1000 mm (40") 1500 mm (60") |
Communication | DPDT relay DC PNP max 350 mA |
Certificates / Approvals | ATEX, FM, CSA, CSA C/US, IEC Ex, NEPSI, INMETRO, EAC |
Options | Sliding sleeve available |
Returns Policy