Endress+Hauser
Endress+Hauser Vibronic Point level detection Liquiphant FTL51H
REQUEST A QUOTE
Process temperature | -50 °C...+150 °C (-58 °F...+302 °F) |
---|---|
Process pressure / max. overpressure limit | Vacuum...64 bar (Vacuum...928 psi) |
Min. density of medium | 0.5g/cm³ (0.4g/cm³ optional) |
Measuring principle | Vibration Liquids |
Characteristic / Application | Premium device for point level detection in hygienic/aseptic applications. Focus Food & Beverage and Life Sciences. Compact sensor version with an optional pipe extension up to 3 m (9,85 ft). Modular & completely welded housing concept, Wide range of certificates. |
Specialities | Plug and play functionalities, Surface finish: mechanical or electro-polished, Density/Concentration measurement, SIL 2/3 according to IEC 61508 |
Supply / Communication | PROFIBUS PA, 19 ..253V AC, 10...55V DC-PNP, 19...253V AC or 19...55V DC with relay DPDT, 8/16mA, NAMUR, PFM |
Ambient temperature | -50 °C...+70 °C (-58 °F...+158 °F) |
Process temperature | -50 °C...+150 °C (-58 °F...+302 °F) |
Process pressure / max. overpressure limit | Vacuum...64 bar (Vacuum...928 psi) |
Min. density of medium | 0.5g/cm³ (0.4g/cm³ optional) |
Main wetted parts | 316L |
Process connection | Threads (for weld-in adapter): G3/4A, G1A, Flange: DN25...DN100, ASME 1"...4", JIS 25A...100A |
Process connection hygienic | Tri-Clamp, DIN 11851, DIN11864-1 Ingold, Flush mount, DRD, SMS1145, Varivent (Varinline) |
Sensor length | Short tube (Liquiphant II) 148mm…3000mm (6,00…118") |
Communication | PROFIBUS PA |
Certificates / Approvals | ATEX, IEC Ex, FM, CSA C/US, TIIS, INMETRO Ex, NEPSI Ex |
Safety approvals | Overfill protection WHG, SIL 2/ SIL 3 |
Design approvals | Inspection certificate 3.1, EN10204, CoC ASME BPE, Conformity to cGMP, EU Food Contact Material (EC) 1935/2004, US Food Contact Material FDA CFR 21, CN Food Contact Material GB 4806, Declaration of Conformity ASME B31.3, AD2000, CRN approval |
Hygienic approvals | 3-A, EHEDG, CoC-ASME BPE |
Marine approval | GL/ ABS/ DNV |
Options | Customized settings (Density) |
Components | FTL325P/FTL375P Interface PFM FTL325N/FTL375N Interface NAMUR |
Successor | FTL63 |
Measuring principle | Vibration Density |
Characteristic / Application | Liquiphant M Density with Density Computer FML621 Temperature and pressure measurement Modular & completely welded housing concept Focus Food & Pharma Surface up to 0.3 µ Variable sensor length up to 3 m (6 m option) |
Supply / Communication | Transmitter power supply (MUS) |
Ambient temperature | -50...70°C -50...60°C for hazardous applications |
Process temperature | 0...80°C (validity of accuracy data) -50...0°C / 80...150°C (with reduced technical data) |
Process pressure | 0...25 bar >25...64 bar (with reduced technical data) |
Wetted parts | 316L |
Hygienic | 3A EHEDG |
Sensor length | 115...3000 mm >3000...6000 mm (Option) |
Output | Pulse |
Certificates / Approvals | ATEX, FM, CSA C/US, IEC Ex, TIIS, INMETRO, NEPSI |
Specialities | Commissioning with ReadWin2000 |
Components | Density Computer FML621 |
Other approvals and certificates | SIL2/ SIL3 |
Returns Policy