Process temperature | -50 °C...+150 °C (-58 °F...+302 °F) up to 230 °C / 450°F on request |
---|---|
Process pressure / max. overpressure limit | Vacuum...40 bar (Vacuum...580 psi) |
Min. density of medium | 0.5g/cm³ (0.4g/cm³ optional) |
Measuring principle | Vibration Liquids |
Characteristic / Application | High protection against aggressive media by using antistatic coating Modular housing concept wide range of process connections Analogue and bus interfaces Extensive certificate range (e.g.Ex,WHG) pipe extension up to 3m (6m option) |
Specialities | Foamdetection Detekt a densitychange second line of defense |
Supply / Communication | PROFIBUS PA 19...253V AC, 2-wire 10...55V DC-PNP, 3-wire DPDT, 19...253V AC, 10...55V DC 8/16mA, 11...36V DC NAMUR PFM, 2-wire NAMUR with testbutton |
Ambient temperature | -50 °C...+70 °C (-58 °C...+158 °F) |
Process temperature | -50 °C...+150 °C (-58 °F...+302 °F) up to 230 °C / 450°F on request |
Process pressure / max. overpressure limit | Vacuum...40 bar (Vacuum...580 psi) |
Min. density of medium | 0.5g/cm³ (0.4g/cm³ optional) |
Main wetted parts | ECTFE PFA (Edlon) PFA (Rubyred) PFA (conductive) Enamel |
Process connection | Flange: DN25...DN100, ASME 1"...3", JIS RF10 K 50 |
Process connection hygienic | FDA conform with PFA (Edlon) |
Sensor length | ECTFE, PFA 130mm, 148mm...3000mm (ECTFE, PFA 5.12", 5.83"...118") Enamel 130mm, 148mm...1200mm (Enmal 5.12", 5.83"...47.24") |
Communication | PROFIBUS PA 19...253V AC 10...55V DC-PNP 19...253V AC bzw 10...55V DC 8/16mA, 11...36V DC NAMUR PFM |
Certificates / Approvals | ATEX, FM, CSA C/US, IEC Ex, TIIS, INMETRO, NEPSI |
Safety approvals | SIL2/ SIL3 |
Design approvals | EN 10204-3.1 |
Marine approval | GL/ ABS/ DNV |
Options | Heavy duty stainless steel housing mainly for the oil and gas industry |
Components | FTL325P/FTL375P Interface PFM FTL325N/FTL375N Interface NAMUR |
Measuring principle | Vibration Density |
Characteristic / Application | Liquiphant M Density with Density Computer FML621 Temperature and pressure measurement High protection against aggressive media by using antistatic coating Modular housing concept Wide range of process connections Pipe extension up to 3 m (6 m option) |
Supply / Communication | Transmitter power supply (MUS) |
Ambient temperature | -50...80°C -50...60°C for hazardous applications |
Process temperature | 0...80 °C (validity of accuracy data) -50...0°C / 80...150 °C (with reduced technical data) |
Process pressure | 0...25 bar >25...40 bar (with reduced technical data) |
Wetted parts | ECTFE, PFA and Enamel |
Sensor length | 115...3000 mm (depends by the covering) |
Output | Pulse |
Certificates / Approvals | ATEX, FM, CSA C/US, IEC Ex, TIIS, INMETRO, NEPSI |
Specialities | Commissioning with ReadWin2000 |
Components | Density Computer FML621 |
Measuring range | Density range: 0.3 to 2 g/cm³ |
Other approvals and certificates | SIL2/ SIL3 |