Endress+Hauser
Endress+Hauser Vibronic Point level detection Liquiphant FTL51
REQUEST A QUOTE
Process temperature | -50 °C...+150 °C (-58 °F...+302 °F) |
---|---|
Process pressure / max. overpressure limit | Vacuum...100 bar |
Min. density of medium | 0.5g/cm³(0.4g/cm³ optional) |
Measuring principle | Vibration Liquids |
Characteristic / Application | Modular housing concept wide range of process connections Analogue and bus interfaces Extensive certificate range (e.g. Ex,WHG) pipe extension up to 3m (6m option) |
Specialities | Foamdetection Detect a densitychange second line of defense |
Supply / Communication | PROFIBUS PA 19...253V AC 10...55V DC-PNP 19...253V AC or 10...55V DC 8/16mA, 11...36V DC NAMUR PFM |
Ambient temperature | -50 °C...+70 °C (-58 °F...+158 °F) |
Process temperature | -50 °C...+150 °C (-58 °F...+302 °F) |
Process pressure / max. overpressure limit | Vacuum...100 bar |
Min. density of medium | 0.5g/cm³(0.4g/cm³ optional) |
Main wetted parts | 316L / Alloy |
Process connection | Thread: G3/4A, G1A, R3/4", R1, NPT3/4, NPT1 Flange: DN25...DN100, ASME 1"...4", JIS 25A...100A |
Process connection hygienic | Tri-Clamp ISO2852 |
Sensor length | Length 130mm (5.12") (Liquiphant II) 148mm...6000mm (5.83"...236") |
Communication | PROFIBUS PA 19...253V AC 10...55V DC-PNP 19...253V AC bzw 10...55V DC 8/16mA, 11...36V DC NAMUR PFM |
Certificates / Approvals | ATEX, FM, CSA C/US, IEC Ex, TIIS, INMETRO, NEPSI |
Safety approvals | SIL2/ SIL3 |
Design approvals | EN 10204-3.1 NACE MR0175, MR0103 ASME B31.3 AD2000 |
Marine approval | GL/ ABS/ DNV |
Options | Heavy duty stainless steel housing mainly for the oil and gas industry |
Components | FTL325P/FTL375P Interface PFM FTL325N/FTL375N Interface NAMUR |
Successor | Liquiphant FTL51B |
Measuring principle | Vibration Density |
Characteristic / Application | Liquiphant M Density with Density Computer FML621 Temperature and pressure measurement Modular housing concept Wide range of process connections Pipe extension up to 3 m (6 m option) |
Supply / Communication | Transmitter power supply (MUS) |
Ambient temperature | -50...70°C -50...60°C for hazardous applications |
Process temperature | 0...80°C (validity of accuracy data) -50...0°C / 80...150 °C (with reduced technical data) |
Process pressure | 0...25 bar >25..100 bar (with reduced technical data) |
Wetted parts | 316L/C4 |
Sensor length | 115...3000 mm >3000...6000 mm (Option) |
Output | Pulse |
Certificates / Approvals | ATEX, FM, CSA C/US, IEC Ex, TIIS, INMETRO, NEPSI |
Specialities | Commissioning with ReadWin2000 |
Components | Density Computer FML621 |
Other approvals and certificates | SIL2/ SIL3 |