Endress+Hauser
Endress+Hauser Ultrasonic measurement Time-of-Flight Prosonic FMU44
REQUEST A QUOTE
Accuracy | +/- 4mm or +/- 0,2 % of set measuring range |
---|---|
Process temperature | -40 °C ... 80 °C (-40 °F ... 176 °F) |
Process pressure / max. overpressure limit | 0,7 bar ... 2,5 bar abs (10 psi ... 36 psi) |
Max. measurement distance | Liquids: 20 m (66 ft), Solids: 10 m (33 ft) |
Main wetted parts | PVDF |
Measuring principle | Ultrasonic |
Characteristic / Application | Compact ultrasonic transmitter |
Supply / Communication | 2-wire HART |
Accuracy | +/- 4mm or +/- 0,2 % of set measuring range |
Ambient temperature | -40 °C ... 80 °C (-40 °F ... 176 °F) |
Process temperature | -40 °C ... 80 °C (-40 °F ... 176 °F) |
Process pressure / max. overpressure limit | 0,7 bar ... 2,5 bar abs (10 psi ... 36 psi) |
Main wetted parts | PVDF |
Process connection | Flange DN100, ASME 4", JIS 10K 100 DN150, ASME 6", JIS 10K 150 DN200, ASME 8", JIS 10K 200 Mounting bracket |
Blocking distance | 0.5 m (1.9 ft) |
Max. measurement distance | Liquids: 20 m (66 ft), Solids: 10 m (33 ft) |
Communication | 4...20 mA HART |
Certificates / Approvals | ATEX, FM, CSA, INMETRO, NEPSI |
Application limits | Fast filling and discharging rate: FMU90 + FDU9x Level limit detection: FMU90 + FDU9x |
Measuring principle | Ultrasonic |
Characteristic / Application | Compact ultrasonic transmitter |
Supply / Communication | 2-wire HART |
Accuracy | +/- 4mm or +/- 0,2 % of set measuring range |
Ambient temperature | -40 °C ... 80 °C (-40 °F ... 176 °F) |
Process temperature | -40 °C ... 80 °C (-40 °F ... 176 °F) |
Process pressure / max. overpressure limit | 0,7 bar ... 2,5 bar abs (10 psi ... 36 psi) |
Main wetted parts | PVDF |
Process connection | Flange DN100, ASME 4", JIS 10K 100 DN150, ASME 6", JIS 10K 150 DN200, ASME 8", JIS 10K 200 Mounting bracket |
Blocking distance | 0.5 m (1.9 ft) |
Max. measurement distance | Liquids: 20 m (66 ft), Solids: 10 m (33 ft) |
Communication | 4...20 mA HART |
Certificates / Approvals | ATEX, FM, CSA, INMETRO, NEPSI |
Application limits | Take notice of range diagram |
Returns Policy