Endress+Hauser Ultrasonic measurement Time-of-Flight Prosonic FMU40

Write a Review

REQUEST A QUOTE

Endress+Hauser Ultrasonic measurement Time-of-Flight Prosonic FMU40
Accuracy+/- 2 mm or +/- 0.2 % of set measuring range 1)
Process temperature-40 °C ... 80 °C
(-40 °F ... 176 °F)
Process pressure / max. overpressure limit0.7 bar ... 3 bar abs
(10 psi ... 44 psi)
Max. measurement distanceLiquids: 5 m (16 ft),
Solids: 2 m (6.6 ft)
Main wetted partsPVDF
Measuring principleUltrasonic
Characteristic / ApplicationCompact ultrasonic transmitter
Supply / Communication2-wire HART
Accuracy+/- 2 mm or +/- 0.2 % of set measuring range
Ambient temperature-40 °C ... 80 °C
(-40 °F ... 176 °F)
Process temperature-40 °C ... 80 °C
(-40 °F ... 176 °F)
Process pressure / max. overpressure limit0.7 bar ... 3 bar abs
(10 psi ... 44 psi)
Main wetted partsPVDF
Process connectionG / NPT 1 1/2"
Blocking distance0.25 m (0.8 ft)
Max. measurement distanceLiquids: 5 m (16 ft),
Solids: 2 m (6.6 ft)
Communication4...20 mA HART
Certificates / ApprovalsATEX, FM, CSA, TIIS, INMETRO, NEPSI
Application limitsFor higher resistance:
FMU42/FDU9x
Foam / high turbulence possible:
FMU41/FDU91
Fast filling and discharging rate:
FMU90 + FDU9x
Level limit detection:
FMU90 + FDU9x
Measuring principleUltrasonic
Characteristic / ApplicationCompact ultrasonic transmitter
Supply / Communication2-wire HART
Accuracy+/- 2 mm or +/- 0.2 % of set measuring range 1)
Ambient temperature-40 °C ... 80 °C
(-40 °F ... 176 °F)
Process temperature-40 °C ... 80 °C
(-40 °F ... 176 °F)
Process pressure / max. overpressure limit0.7 bar ... 3 bar abs
(10 psi ... 44 psi)
Main wetted partsPVDF
Process connectionG / NPT 1 1/2"
Blocking distance0.25 m (0.8 ft)
Max. measurement distanceLiquids: 5 m (16 ft),
Solids: 2 m (6.6 ft)
Communication4...20 mA HART
Certificates / ApprovalsATEX, FM, CSA, TIIS, INMETRO, NEPSI
Application limitsTake notice of range diagram
Measuring principleUltrasonic Limit
Characteristic / ApplicationCompact ultrasonic transmitter
Supply / Communication2-wire HART
Ambient temperature-40 °C...+80 °C
(-40 °F...+176 °F)
Process temperature-40 °C...+80 °C
(-40 °F...+176 °F)
Process pressure / max. overpressure limit0.7 bar...3 bar abs
(10 psi...44 psi)
Main wetted partsPVDF
Process connectionG / NPT 1 1/2"
Blocking distance0.25 m (0.8 ft)
Communication4...20 mA HART
Certificates / ApprovalsATEX, FM, CSA, INMETRO, NEPSI
Application limitsTake notice of range diagram
Measuring principleUltrasonic Limit
Characteristic / ApplicationCompact ultrasonic transmitter
Supply / Communication2-wire HART
Ambient temperature-40 °C...+80 °C
(-40 °F...+176 °F)
Process temperature-40 °C...+80 °C
(-40 °F...+176 °F)
Process pressure / max. overpressure limit0.7 bar...3 bar abs
(10 psi...44 psi)
Main wetted partsPVDF
Process connectionG / NPT 1 1/2"
Blocking distance0.25 m (0.8 ft)
Communication4...20 mA HART
Certificates / ApprovalsATEX, FM, CSA, INMETRO, NEPSI
Application limitsTake notice of range diagram
Measuring principleUltrasonic
Product headlineCompact ultrasonic measuring instrument
Cost effective solution for open channel
Max. measurement errorLow accuracy
Measuring range0,25...5m [0.8...16ft]
Max. process pressureatm.
Medium temperature range-40°C ... 80°C
(-40°F...176°F)
Degree of protectionIP68
Outputs4...20mA(Hart),PA,FF
Inputs2-wire 16-36V DC,
4-wire 16-36V DC,
90-253V AC 50/60Hz
Digital communicationPROFIBUS PA, FOUNDATION Fieldbus
Hazardous area approvalsATEX, FM, CSA