Endress+Hauser
Endress+Hauser Ultrasonic measurement Time-of-Flight Prosonic FDU93
REQUEST A QUOTE
Process temperature | -40 °C ... 95 °C (-40 °F ... 203 °F) |
---|---|
Process pressure / max. overpressure limit | 0.7 bar ... 3 bar abs (10 psi ... 43 psi) |
Max. measurement distance | Liquids: 25 m (85 ft), Solids: 15 m (50 ft) |
Accuracy | +/- 2 mm + 0.17% of measured distance |
Main wetted parts | UP (unsaturated polyester) Silicon / Al PTFE coated |
Measuring principle | Ultrasonic |
Characteristic / Application | Separated version with field housing or top hat rail housing for control cabinet instrumentation, 300 m in-between sensor and transmitter |
Supply / Communication | 4-wire (HART, Profibus DP) |
Accuracy | +/- 2 mm + 0.17% of measured distance |
Ambient temperature | -40 °C ... 95 °C (-40 °F ... 203 °F) |
Process temperature | -40 °C ... 95 °C (-40 °F ... 203 °F) |
Process pressure / max. overpressure limit | 0.7 bar ... 3 bar abs (10 psi ... 43 psi) |
Main wetted parts | UP (unsaturated polyester) Silicon / Al PTFE coated |
Process connection | G / NPT 1" |
Blocking distance | 0.6 m (2 ft) |
Max. measurement distance | Liquids: 25 m (85 ft), Solids: 15 m (50 ft) |
Communication | Transmitter: 4...20 mA HART Profibus DP |
Certificates / Approvals | ATEX, FM, CSA, IEC Ex, INMETRO, NEPSI, EAC Ex |
Options | Second 4...20 mA output |
Components | Transmitter: FMU90, FMU95 |
Application limits | For tank farms scanner: FMU95 |
Measuring principle | Ultrasonic |
Characteristic / Application | Separated version with field housing or top hat rail housing for control cabinet instrumentation, 300m in-between sensor and transmitter |
Supply / Communication | 4-wire (HART , Profibus DP) |
Accuracy | +/- 2mm + 0.17% of measured distance |
Ambient temperature | -40 °C ... 95 °C (-40 °F ... 203 °F) |
Process temperature | -40 °C ... 95 °C (-40 °F ... 203 °F) |
Process pressure / max. overpressure limit | 0.7 bar ... 3 bar abs (10 psi ... 43 psi) |
Main wetted parts | UP (unsaturated polyester) Silicon / Al PTFE coated |
Process connection | G / NPT 1" |
Blocking distance | 0.6 m (2 ft) |
Max. measurement distance | Liquids: 25 m (85 ft), Solids: 15 m (50 ft) |
Communication | Transmitter: 4 ... 20 mA HART Profibus DP |
Certificates / Approvals | ATEX, FM, CSA, IEC Ex, INMETRO, NEPSI, EAC Ex |
Options | Second 4...20mA output |
Components | Transmitter: FMU90 |
Returns Policy