Endress+Hauser
Endress+Hauser TR65 Explosion-proof Pt100 Thermometer
REQUEST A QUOTE
Accuracy | class A acc. to IEC 60751 class AA acc. to IEC 60751 |
---|---|
Response time | t50 = 2 s t90 = 5 s |
Max. process pressure (static) | at 20 °C: 80 bar (1.160 psi) |
Operating temperature range | PT100 TF StrongSens: -50 °C ...500 °C (-58 °F ...932 °F) PT100 WW: -200 °C ...600 °C (-328 °F ...1.112 °F) PT100 TF: -50 °C ...400 °C (-58 °F ...752 °F) |
Max. immersion length on request | up to 30.000,00 mm (1.181,10'') |
Measuring principle | Resistance Temperature Detector |
Characteristic / Application | metric style modular temperature assembly for heavy duty applications suitable for hazardous areas threaded process connection without neck |
Thermowell / protection tube | without (not intended to use with thermowell) |
Insert / probe | mineral insulated (MI), flexible |
Outer diameter protection tube / Insert | 3,0 mm (0,12'') 6,0 mm (0,24'') |
Max. immersion length on request | up to 30.000,00 mm (1.181,10'') |
Material protection tube/ thermowell | 1.4404 (316L) |
Process connection | male thread: NPT1/2" NPT3/4" M20x1,5 compression fitting: NPT1/2" NPT3/4" |
Tip shape | straight |
Surface roughness Ra | Not defined |
Operating temperature range | PT100 TF StrongSens: -50 °C ...500 °C (-58 °F ...932 °F) PT100 WW: -200 °C ...600 °C (-328 °F ...1.112 °F) PT100 TF: -50 °C ...400 °C (-58 °F ...752 °F) |
Max. process pressure (static) | at 20 °C: 80 bar (1.160 psi) |
Accuracy | class A acc. to IEC 60751 class AA acc. to IEC 60751 |
Response time | t50 = 2 s t90 = 5 s |
Integration head transmitter | yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS) |
Ex - approvals | ATEX II1/2D Ex ia IIIC,II1G Ex ia IIC T6 ATEX II 2 GD Ex d IIC ATEX II 3 G Ex nA IIC T6, II3D IECEx Ex ia IIC T6 Ga/Gb IECEx Ex d IIC T6/T5/T4 IECEx Ex d IIC T6/T5/T4, Ex tD A21 EAC Ex ia IIC T6 Ga + DIP EAC Ex d IIC T6 Gb + DIP NEPSI Ex ia IIC T6, Ex iaD 20 T85-T450 NEPSI Ex d IIC T6 NEPSI Ex nA IIC T6 Explosion proof |
Certification | Gost Metrology SIL (transmitter only) |
Returns Policy