AccuracyStandard acc. to ASTM E-230Special acc. to ASTM E-230Response timedepending on configuration63% rt = 15 sMax. process pressure (static)at 20°C: 100 bar (1.450psi)depends on...
Accuracyclass 1 acc. to IEC 60584class 2 acc. to IEC 60584Response time63% rt = 1,3 sMax. process pressure (static)at 20 °C: 100 bar (1.450 psi)Operating temperature rangeType T:-270 °C ...370...
AccuracyStandard acc. to ASTM E-230Special acc. to ASTM E-230Response time63% rt = 0.3 sMax. process pressure (static)at 20°C: 250 bar (3.626 psi)depends on configurationOperating temperature...
AccuracyStandard acc. to ASTM E-230Special acc. to ASTM E-230Response timedepending on configuration63% rt = 15,0 sMax. process pressure (static)at 20°C: 500 bar (7252 psi)depends on...
Accuracyclass 1 acc. to IEC 60584Response timedepending on configurationMax. process pressure (static)at 20 °C: 400 bar (5.802 psi)Operating temperature rangeType K:max. 1.100 °C(max. 2.012 °F)Type...
Accuracyclass AA acc. to IEC 60751class A acc. to IEC 60751class B acc. to IEC 60751Response timedepending on configurationMax. process pressure (static)at 20 °C: 100 bar (1.450 psi)depends on...
Accuracyclass A acc. to IEC 60751class B acc. to IEC 60751Response time63% rt = 2,0 sMax. process pressure (static)at 20°C: 250 bar (3.626 psi)depends on configurationOperating temperature rangePT...
Accuracyclass AA acc. to IEC 60751class A acc. to IEC 60751class B acc. to IEC 60751Response timedepending on configurationMax. process pressure (static)at 20 °C: 500 bar (7.252 psi)depends on...