Endress+Hauser TH51 Modular TC thermometer, US style

Write a Review

REQUEST A QUOTE

Endress+Hauser TH51 Modular TC thermometer, US style
AccuracyStandard acc. to ASTM E-230
Special acc. to ASTM E-230
Response time63% rt = 0.3 s
Max. process pressure (static)at 20°C: 250 bar (3.626 psi)
depends on configuration
Operating temperature rangeType T:
-270 °C ...370 °C
(-454 °F ...698 °F)
Type J:
-210 °C ...720 °C
(-346 °F ...1.328 °F)
Type E:
-270 °C ...820 °C
(-454 °F ...1.508 °F)
Type K:
-270 °C ...1.150 °C
(-454 °F ...2.102 °F)
Type N:
-270 °C ... 1.150 °C
(-454 °F ...2.102 °F)
Max. immersion length on requestup to 96" (2.438 mm)
others on request
Measuring principleThermocouple
Characteristic / ApplicationUS style
modular temperature assembly
threaded process connection

Thermowell / protection tubewithout (not intended to use with thermowell)
Insert / probemineral insulated (MI), flexible
Outer diameter protection tube / Insert1/8'' (3,18 mm)
3/16''(4,76 mm)
1/4'' (6,35 mm)
3/8'' (9,53 mm)


Max. immersion length on requestup to 96" (2.438 mm)
others on request
Material protection tube/ thermowell316
Alloy 600
Optional coatingNot applicable
Process connectionmale thread:
G1/2"
NPT1/2"
compression fitting:
NPT1/8"
NPT1/4"




Tip shapestraight
Surface roughness RaNot defined
Operating temperature rangeType T:
-270 °C ...370 °C
(-454 °F ...698 °F)
Type J:
-210 °C ...720 °C
(-346 °F ...1.328 °F)
Type E:
-270 °C ...820 °C
(-454 °F ...1.508 °F)
Type K:
-270 °C ...1.150 °C
(-454 °F ...2.102 °F)
Type N:
-270 °C ... 1.150 °C
(-454 °F ...2.102 °F)



Max. process pressure (static)at 20°C: 250 bar (3.626 psi)
depends on configuration
AccuracyStandard acc. to ASTM E-230
Special acc. to ASTM E-230
Response time63% rt = 0.3 s
Integration head transmitteryes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)
Ex - approvalstransmitter only
FM IS
CSA IS
FM/CSA IS
CertificationSIL (transmitter only)
Returns Policy