Endress+Hauser
Endress+Hauser TC66 Explosion-proof TC Thermometer
REQUEST A QUOTE
Accuracy | class 1 acc. to IEC 60584 |
---|---|
Response time | depending on configuration t50 = 3 s t90 = 7 s |
Max. process pressure (static) | at 20 °C: 500 bar (7.252 psi) |
Operating temperature range | Type K: max. 1.100 °C (max. 2.012 °F) Type J: max. 800 °C (max. 1.472 °F) |
Max. immersion length on request | up to 5.000,00 mm (196,85'') |
Measuring principle | Thermocouple |
Characteristic / Application | US style modular temperature assembly for heavy duty applications suitable for hazardous areas with neck incl. thermowell / protection tube (metal) |
Thermowell / protection tube | bar stock (drilled) |
Insert / probe | mineral insulated (MI), flexible |
Outer diameter protection tube / Insert | 20 mm (0,79") 24 mm (0,94") 25 mm (0,98") |
Max. immersion length on request | up to 5.000,00 mm (196,85'') |
Material protection tube/ thermowell | 1.4401 (316) 1.4404 (316L) 1.4571 (316Ti) Alloy C276 Alloy 400 |
Optional coating | Not defined |
Process connection | male thread: NPT3/4" NPT1" flange: ASME 1" 150 RF (B16.5) ASME 1" 300 RF (B16.5) ASME 1" 600 RF (B16.5) ASME 1,5" 150 RF (B16.5) ASME 1,5" 300 RF (B16.5) ASME 1,5" 600 RF (B16.5) ASME 2" 300 RF (B16.5) ASME 2" 600 RF (B16.5) |
Tip shape | straight tapered |
Surface roughness Ra | 1,6 μm (63,0 μin.) |
Operating temperature range | Type K: max. 1.100 °C (max. 2.012 °F) Type J: max. 800 °C (max. 1.472 °F) |
Max. process pressure (static) | at 20 °C: 500 bar (7.252 psi) |
Accuracy | class 1 acc. to IEC 60584 |
Response time | depending on configuration t50 = 3 s t90 = 7 s |
Integration head transmitter | yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS) |
Ex - approvals | ATEX II IECEx NEPSI EAC Ex Explosion proof UKCA |
Certification | Gost Metrology SIL (transmitter only) |
Returns Policy