Endress+Hauser T15 Explosion proof RTD thermometer, US style

Write a Review

REQUEST A QUOTE

Endress+Hauser T15 Explosion proof RTD thermometer, US style
Accuracyclass A acc. to IEC 60751
class B acc. to IEC 60751
Response time63% rt = 3 s
Max. process pressure (static)Not applicable
Operating temperature rangePT100 WW:
-200 °C … 600 °C
(-328 °F … 1.112 °F)
PT100 TF:
-50 °C … 200 °C
(-58 °F … 392 °F)
Max. immersion length on requestup to 100" (2540 mm)
others on request
Measuring principleResistance Temperature Detector
Characteristic / ApplicationExplosion Proof US style
modular temperature assembly
for heavy duty applications
with extension
to be used with existing thermowell



Thermowell / protection tubeto be used with thermowell
Insert / probemineral insulated (MI), flexible
PTFE-insulated, rigid
Outer diameter protection tube / InsertNot applicable
Max. immersion length on requestup to 100" (2540 mm)
others on request
Material protection tube/ thermowellSensor sheath
316/316L
Optional coatingNot defined
Process connectionmale thread:
NPT1/2"
Tip shapestraight
Surface roughness RaNot defined
Operating temperature rangePT100 WW:
-200 °C … 600 °C
(-328 °F … 1.112 °F)
PT100 TF:
-50 °C … 200 °C
(-58 °F … 392 °F)
Max. process pressure (static)Not applicable
Accuracyclass A acc. to IEC 60751
class B acc. to IEC 60751
Response time63% rt = 3 s
Integration head transmitteryes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)
Ex - approvalsFM XP DIP Class I,II,III Div. 1+2, Grp.A-G
FM XP NI DIP Class I,II,III Div. 1+2, Grp.A-G
CSA XP DIP Class I,II,III Div. 1+2, Grp.B-G
CSA XP NI DIP Class I,II,III Div. 1+2, Grp.B-G
FM/CSA XP DIP Class I,II,III Div. 1+2, FM Grp.A-G, CSA Grp.B-G
FM/CSA XP NI DIP Class I,II,III Div.1+2 FM Grp.A-G, CSA Grp.B-G
CSA C/US XP, DIP I, II, III/1/A-G
cCSAus General Purpose
CertificationSIL (transmitter only)
Returns Policy

Related Products

Top