Endress+Hauser
Endress+Hauser SS2100I SS2100i gas analyzer
REQUEST A QUOTE
Measured Variables | Concentration Cell Pressure Cell Temperature |
---|---|
Hazardous area approvals | IECEx / ATEX / CNEx / KC / CCOE / CML Zone 1 |
Measuring principle | TDLAS |
Product Headline | An advanced gas analyzer for hydrogen sulfide (H2S) measurement. The SS2100i uses tunable diode laser absorption spectroscopy (TDLAS) to determine the concentration of the analyte without coming into physical contact with the stream. |
Channels | 1 |
Analyte and Measurement ranges | H2S (Hydrogen Sulfide): 0 to 10 ppmv 0 to 1000 ppmv 0 to 5000 ppmv 0 to 5% volume |
Measured Variables | Concentration Cell Pressure Cell Temperature |
Ambient Temperature range | -20 to 50°C (-4 to 122°F) Optional (i-2 only): -10 to 60°C (14 to 140°F) |
Operating Pressure range | Inlet Pressure: 140 to 350 kPa (20 to 50 psig) Sample Cell: 800 to 1200 mbara or 950 to 1700 mbara (optional) |
Analyzer Wetted materials | 316L stainless steel FKM O-Rings Glass |
Power supply | 120 or 240 VAC ± 10 %, 50 to 60 Hz; 300W |
Communication | Analog Output: Two 4-20mA Isolated, 1200 ohms at 24 VDC max load (measurement value) Analog Input: One 4-20mA Isolated, 1200 ohms at 24 VDC max load (process pressure) Serial: RS232C and Ethernet Protocol: Modbus Gould RTU or Daniel RTU or ASCII Digital Outputs: 5, Concentration Alarm, General Fault, Validation Fail, Validation 1 Active, Validation 2 Active Digital Inputs: 2, Flow Alarm, Validation Request |
Housing materials | Electronics: Copper-free Aluminum Laser/Cell Enclosure: Copper-free Aluminum (i-2 only) Sample System Enclosure: 304 or 316 stainless steel |
Hazardous area approvals | IECEx / ATEX / CNEx / KC / CCOE / CML Zone 1 |
Degree of protection | IP66 |
Product safety | CE |
Metrological approvals | PAC China, Kazakhstan (i-1 only) |
Measuring principle | TDLAS |
Product Headline | An advanced gas analyzer for moisture (H2O) measurement. The SS2100i uses tunable diode laser absorption spectroscopy (TDLAS) to determine the concentration of the analyte without coming into physical contact with the stream. |
Channels | 1 |
Analyte and Measurement ranges | H2O (Moisture): 0 to 10 ppmv 0 to 100 ppmv 0 to 50 ppmv 0 to 5000 ppmv |
Measured Variables | Concentration Moisture Dew Point Cell Pressure Cell Temperature |
Ambient Temperature range | -20 to 50°C (-4 to 122°F) Optional (i-2 only): -10 to 60°C (14 to 140°F) |
Operating Pressure range | Inlet Pressure: 140 to 350 kPa (20 to 50 psig) Sample Cell: 800 to 1200 mbara or 950 to 1700 mbara (optional) |
Analyzer Wetted materials | 316L stainless steel FKM O-Rings Glass |
Power supply | 120 or 240 VAC ± 10 %, 50 to 60 Hz; 300W |
Communication | Analog Output: Two 4-20mA Isolated, 1200 ohms at 24 VDC max load (measurement value) Analog Input: One 4-20mA Isolated, 1200 ohms at 24 VDC max load (process pressure) Serial: RS232C and Ethernet Protocol: Modbus Gould RTU or Daniel RTU or ASCII Digital Outputs: 5, Concentration Alarm, General Fault, Validation Fail, Validation 1 Active, Validation 2 Active Digital Inputs: 2, Flow Alarm, Validation Request |
Housing materials | Electronics: Copper-free Aluminum Laser/Cell Enclosure: Copper-free Aluminum (i-2 only) Sample System Enclosure: 304 or 316 stainless steel |
Hazardous area approvals | IECEx / ATEX / CNEx / KC / CCOE / CML Zone 1 |
Degree of protection | IP66 |
Product safety | CE |
Metrological approvals | PAC China, Kazakhstan (i-1 only) |
Measuring principle | TDLAS |
Product Headline | An advanced gas analyzer for carbon dioxide (CO2) measurement. The SS2100i uses tunable diode laser absorption spectroscopy (TDLAS) to determine the concentration of the analyte without coming into physical contact with the stream. |
Channels | 1 |
Analyte and Measurement ranges | CO2 (Carbon Dioxide): 0 to 10 ppmv 0 to 1000 ppmv 0 to 5000 ppmv 0 to 5% volume 0 to 10% volume 0 to 20% volume |
Measured Variables | Concentration Cell Pressure Cell Temperature |
Ambient Temperature range | -20 to 50°C (-4 to 122°F) Optional (i-2 only): -10 to 60°C (14 to 140°F) |
Operating Pressure range | Inlet Pressure: 140 to 350 kPa (20 to 50 psig) Sample Cell: 800 to 1200 mbara or 950 to 1700 mbara (optional) |
Analyzer Wetted materials | 316L stainless steel FKM O-Rings Glass |
Power supply | 120 or 240 VAC ± 10 %, 50 to 60 Hz; 300W |
Communication | Analog Output: Two 4-20mA Isolated, 1200 ohms at 24 VDC max load (measurement value) Analog Input: One 4-20mA Isolated, 1200 ohms at 24 VDC max load (process pressure) Serial: RS232C and Ethernet Protocol: Modbus Gould RTU or Daniel RTU or ASCII Digital Outputs: 5, Concentration Alarm, General Fault, Validation Fail, Validation 1 Active, Validation 2 Active Digital Inputs: 2, Flow Alarm, Validation Request |
Housing materials | Electronics: Copper-free Aluminum Laser/Cell Enclosure: Copper-free Aluminum (i-2 only) Sample System Enclosure: 304 or 316 stainless steel |
Hazardous area approvals | IECEx / ATEX / CNEx / KC / CCOE / CML Zone 1 |
Degree of protection | IP66 |
Product safety | CE |
Metrological approvals | PAC China, Kazakhstan (i-1 only) |
Measuring principle | TDLAS |
Product Headline | An advanced gas analyzer for ammonia (NH3) measurement. The SS2100i uses tunable diode laser absorption spectroscopy (TDLAS) to determine the concentration of the analyte without coming into physical contact with the stream. |
Channels | 1 |
Analyte and Measurement ranges | NH3 (Ammonia): 0 to 5 ppmv |
Measured Variables | Concentration Cell Pressure Cell Temperature |
Ambient Temperature range | -20 to 50°C (-4 to 122°F) Optional (i-2 only): -10 to 60°C (14 to 140°F) |
Operating Pressure range | Inlet Pressure: 140 to 350 kPa (20 to 50 psig) Sample Cell: 800 to 1200 mbara or 950 to 1700 mbara (optional) |
Analyzer Wetted materials | 316L stainless steel FKM O-Rings Glass |
Power supply | 120 or 240 VAC ± 10 %, 50 to 60 Hz; 300W |
Communication | Analog Output: Two 4-20mA Isolated, 1200 ohms at 24 VDC max load (measurement value) Analog Input: One 4-20mA Isolated, 1200 ohms at 24 VDC max load (process pressure) Serial: RS232C and Ethernet Protocol: Modbus Gould RTU or Daniel RTU or ASCII Digital Outputs: 5, Concentration Alarm, General Fault, Validation Fail, Validation 1 Active, Validation 2 Active Digital Inputs: 2, Flow Alarm, Validation Request |
Housing materials | Electronics: Copper-free Aluminum Laser/Cell Enclosure: Copper-free Aluminum (i-2 only) Sample System Enclosure: 304 or 316 stainless steel |
Hazardous area approvals | IECEx / ATEX / CNEx / KC / CCOE / CML Zone 1 |
Degree of protection | IP66 |
Product safety | CE |
Metrological approvals | PAC China, Kazakhstan (i-1 only) |
Measuring principle | TDLAS |
Product Headline | An advanced gas analyzer for acetylene (C2H2) measurement. The SS2100i uses tunable diode laser absorption spectroscopy (TDLAS) to determine the concentration of the analyte without coming into physical contact with the stream. |
Channels | 1 |
Analyte and Measurement ranges | C2H2 (Acetylene): 0 to 5 ppmv (minimum) 0 to 3000 ppmv (maximum) |
Measured Variables | Concentration Cell Pressure Cell Temperature |
Ambient Temperature range | -20 to 50°C (-4 to 122°F) Optional (i-2 only): -10 to 60°C (14 to 140°F) |
Operating Pressure range | Inlet Pressure: 140 to 350 kPa (20 to 50 psig) Sample Cell: 800 to 1200 mbara or 950 to 1700 mbara (optional) |
Analyzer Wetted materials | 316L stainless steel FKM O-Rings Glass |
Power supply | 120 or 240 VAC ± 10 %, 50 to 60 Hz; 300W |
Communication | Analog Output: Two 4-20mA Isolated, 1200 ohms at 24 VDC max load (measurement value) Analog Input: One 4-20mA Isolated, 1200 ohms at 24 VDC max load (process pressure) Serial: RS232C and Ethernet Protocol: Modbus Gould RTU or Daniel RTU or ASCII Digital Outputs: 5, Concentration Alarm, General Fault, Validation Fail, Validation 1 Active, Validation 2 Active Digital Inputs: 2, Flow Alarm, Validation Request |
Housing materials | Electronics: Copper-free Aluminum Laser/Cell Enclosure: Copper-free Aluminum (i-2 only) Sample System Enclosure: 304 or 316 stainless steel |
Hazardous area approvals | IECEx / ATEX / CNEx / KC / CCOE / CML Zone 1 |
Degree of protection | IP66 |
Product safety | CE |
Metrological approvals | PAC China, Kazakhstan (i-1 only) |