Endress+Hauser Spectrometer Memosens Wave CAS80E
REQUEST A QUOTE
Measurement range | Depending on the path length and the application the measuring range vary: TOCeq: 0 to 400 mg/l CODeq: 0 to 20 000 mg/l BODeq: 0 to 5000 mg/l SAC254: 0 to 1000 /m TU: 0 to 800 FAU TSS: 0 to 10 000 mg/l NO3-N: 0 to 500 mg/l APHA/Hazen: 0 to 500 Hazen |
---|---|
Process temperature | 0 to 50°C 32 to 122 °F |
Process pressure | 0.5 to 10 bar abs. 7.3 to 145 psi |
Measuring method | UV/VIS Absorbance at 200 to 800 nm |
Measuring principle | Absorption |
Application | Monitoring of WWTP in- and outlet Drinking water and surface water |
Installation | Insitu (immersion in process), extractive with sample and flow cell |
Characteristic | Insitu (immersion in process), extractive with sample and flow cell UV/VIS spectrometer for measurement of TOCeq, CODeq, BODeq, SAC254, TU/TSS, Nitrate, APHA/Hazen color |
Measurement range | "Depending on the path length and the application the measuring range vary: TOCeq: 0 to 400 mg/l CODeq: 0 to 20 000 mg/l BODeq: 0 to 5000 mg/l SAC254: 0 to 1000 /m TU: 0 to 800 FAU TSS: 0 to 10 000 mg/l NO3-N: 0 to 500 mg/l APHA/Hazen: 0 to 500 Hazen |
Measuring principle | UV/VIS absorbance at 200 to 800 nm |
Design | 40 mm |
Material | Housing: stainless steel or titanium Windows: sapphire or quartz O-rings: EPDM |
Dimension | 571.4 x 40 mm 21.5 x 1.6 in |
Process temperature | 0 to 50°C 32 to 122 °F |
Process pressure | 0.5 to 10 bar abs. 7.3 to 145 psi |
Temperature sensor | -20 to 60°C -4 to 140 °F |
Connection | G1 and NPT 3/4" |
Ingress protection | IP68 |
Measuring principle | UV absorbance |
Application | Monitoring of WWTP in- and outlet, drinking water and surface water |
Characteristic | Insitu (immersion in process) Extractive with sample and flow cell UV/VIS spectrometer for measurement of TOCeq, CODeq, BODeq, SAC254, TU/TSS, Nitrate, APHA/Hazen color |
Measurement range | Depending on the path length and the application the measuring range vary: TOCeq: 0 to 400 mg/l CODeq: 0 to 20 000 mg/l BODeq: 0 to 5000 mg/l SAC254: 0 to 1000 /m TU: 0 to 800 FAU TSS: 0 to 10 000 mg/l NO3-N: 0 to 500 mg/l APHA/Hazen: 0 to 500 Hazen |
Design | 40 mm |
Material | Housing: stainless steel or titanium Windows: sapphire or quartz O-rings: EPDM |
Process temperature | 0 to 50°C 32 to 122 °F |
Process pressure | 0.5 to 10 bar abs. 7.3 to 145 psi |
Temperature sensor | -20 to 60°C -4 to 140 °F |
Connection | G1 and NPT 3/4" |
Ingress protection | IP68 |
Measuring principle | UV absorbance |
Characteristic | Insitu (immersion in process), extractive with sample and flow cell UV/VIS spectrometer for measurement of TOCeq, CODeq, BODeq, SAC254, TU/TSS, Nitrate, APHA/Hazen color |
Measuring method | UV/VIS Absorbance at 200 to 800 nm |
Size | 571.4 x 40 mm 21.5 x 1.6 in |
Design | 40 mm |
Process temperature | 0 to 50°C 32 to 122 °F |
Ambient temperature | -20 to 60°C -4 to 140 °F |
Process pressure | 0.5 to 10 bar abs. 7.3 to 145 psi |
Specials | G1, NPT3/4 IP68 (1m/3,3ft) water column with 1N KCl during 60 days |
Application | Monitoring of WWTP in- and outlet Drinking water and surface water |
Measurement range | Depending on the path length and the application the measuring range vary: TOCeq: 0 to 400 mg/l CODeq: 0 to 20 000 mg/l BODeq: 0 to 5000 mg/l SAC254: 0 to 1000 /m TU: 0 to 800 FAU TSS: 0 to 10 000 mg/l NO3-N: 0 to 500 mg/l APHA/Hazen: 0 to 500 Hazen |