Endress+Hauser Servo tank gauging instrument Proservo NMS83

Write a Review

REQUEST A QUOTE

Endress+Hauser Servo tank gauging instrument Proservo NMS83
Accuracyup to 0.4 mm
Process temperature-200°C...200°C
(-328°F...392°F)
Process pressure / max. overpressure limit6 bar abs
Max. measurement distance22 m (72 ft)
Main wetted parts316L, AlloyC276, PTFE
Measuring principleServo / Float Tank Gauging
Characteristic / ApplicationServo Tank Gauging: High precision measurement for liquid level,
interface, spot density and density profile for hygienic applications
SpecialitiesCustody transfer level measurement
Interface measurement
Spot density, density profile measurement
Supply / Communication85-264VAC
52-74VAC
19-64VDC
Accuracyup to 0.4 mm
Ambient temperatureStandard:
-40°C…60°C
(-40°F...140°F)
For calibration to regulatory
standards:
-25°C…55°C
(-13°F...131°F)
Process temperature-200°C...200°C
(-328°F...392°F)
Process pressure / max. overpressure limit6 bar abs
Main wetted parts316L, AlloyC276, PTFE
Process connectionFlange:
DN80/3" / DN150/6"
Max. measurement distance22 m (72 ft)
CommunicationOutputs:
Fieldbus: Modbus RS485, V1, WM550
HART, BPM and TRL/2 (via GE option)
Analog 4-20mA output (Exi/ Exd)
Relay output (Exd)
Inputs:
Analog 4-20mA input (Exi/ Exd)
2-, 3-, 4-wire RTD input
Discrete input (Exd, passive/ active)
Certificates / ApprovalsATEX, FM, IEC Ex, EAC, JPN Ex, KC Ex,
INMETRO, NEPSI, UK Ex
Safety approvalsOverfill protection WHG
SIL
Design approvalsEN 10204-3.1
NACE MR0175, MR0103
Metrological approvals and certificatesOIML, NMi, PTB
OptionsRedundant fieldbus
Weather protection cover
CIP (Cleaning in Place)
Relief valve
Gas purging nozzle connection
Pressure gauge
Cleaning nozzle connection
Application limitsStilling well or guide wires for turbulent
application
Recommend PTFE displacer for high
viscosity application
Interface measurement requires min. difference of 0.100 g/ml
between layers
Measuring principleServo / Float Tank Gauging
Characteristic / ApplicationServo Tank Gauging: High precision measurement for liquid level,
interface, spot density and density profile for hygienic applications
Supply / Communication85-264VAC
Ambient temperatureStandard:
-40°C…60°C
(-40°F...140°F)
For calibration to regulatory
standards:
-25°C…55°C
(-13°F...131°F)
Process temperature-200°C...200°C
(-328°F...392°F)
Process pressure6 bar abs
Wetted parts316L, AlloyC276, PTFE
OutputOutputs:
Fieldbus: Modbus RS485, V1, HART
Analog 4-20mA output (Exi/ Exd)
Relay output (Exd)
Inputs:
Analog 4-20mA input (Exi/ Exd)
2-, 3-, 4-wire RTD input
Discrete input (Exd, passive/ active)
Certificates / ApprovalsATEX, FM, IEC Ex, NEPSI, EAC
OptionsRedundant fieldbus
Weather protection cover
CIP (Cleaning in Place)
Relief valve
Gas purging nozzle connection
Pressure gauge
Cleaning nozzle connection
SpecialitiesCustody transfer level measurement
Interface measurement
Spot density, density profile measurement
Measuring range22 m (72 ft)
Other approvals and certificatesEN 10204-3.1
NACE MR0175, MR0103
OIML, NMi, PTB
Returns Policy