Endress+Hauser Servo tank gauging instrument Proservo NMS80

Write a Review

REQUEST A QUOTE

Endress+Hauser Servo tank gauging instrument Proservo NMS80
Accuracyup to 0.4 mm
Process temperature-200°C...200°C
(-328°F...392°F)
Process pressure / max. overpressure limit0,2...6 bar abs
Max. measurement distance36 m (118 ft)
Main wetted parts316L, AlloyC276, PTFE
Measuring principleServo / Float Tank Gauging
Characteristic / ApplicationServo Tank Gauging: High precision measurement for liquid level, interface, spot density, profile density
SpecialitiesCustody transfer level measurement
Interface measurement
Spot density, density profile measurement
Supply / Communication85-264VAC
52-74VAC
19-64VDC
Accuracyup to 0.4 mm
Ambient temperatureStandard:
-40°C…60°C
(-40°F...140°F)
For calibration to regulatory
standards:
-25°C…55°C
(-13°F...131°F)
Process temperature-200°C...200°C
(-328°F...392°F)
Process pressure / max. overpressure limit0,2...6 bar abs
Main wetted parts316L, AlloyC276, PTFE
Process connectionFlange:
DN80/3" / DN150/6"
Max. measurement distance36 m (118 ft)
CommunicationOutputs:
Fieldbus: Modbus RS485, V1, WM550
HART, BPM and TRL/2 (via GE option)
Analog 4-20mA output (Exi/ Exd)
Relay output (Exd)
Inputs:
Analog 4-20mA input (Exi/ Exd)
2-, 3-, 4-wire RTD input
Discrete input (Exd, passive/ active)
Certificates / ApprovalsATEX, FM, IEC Ex, EAC, JPN Ex, KC Ex,
INMETRO, NEPSI, UK Ex
Safety approvalsOverfill protection WHG
SIL
Metrological approvals and certificatesOIML, NMi, PTB
OptionsRedundant fieldbus
Weather protection cover
Guide wire assembly
Relief valve
Gas purging nozzle connection
Pressure gauge
Cleaning nozzle connection
Application limitsStilling well or guide wires for turbulent
application
Recommend PTFE displacer for high
viscosity application
Recommend AlloyC276 displacer for corrosive application
Interface measurement requires min. difference of 0.100 g/ml
between layers
Measuring principleServo / Float Tank Gauging
Characteristic / ApplicationServo Tank Gauging: High precision measurement for liquid level, interface, spot density, profile density
Supply / Communication85-264VAC
Ambient temperatureStandard:
-40°C…60°C
(-40°F...140°F)
For calibration to regulatory
standards:
-25°C…55°C
(-13°F...131°F)
Process temperature-200°C...200°C
(-328°F...392°F)
Process pressure0.2...6 bar abs
Wetted parts316L, AlloyC276, PTFE
OutputOutputs:
Fieldbus: Modbus RS485, V1, HART
Analog 4-20mA output (Exi/ Exd)
Relay output (Exd)
Inputs:
Analog 4-20mA input (Exi/ Exd)
2-, 3-, 4-wire RTD input
Discrete input (Exd, passive/ active)
Certificates / ApprovalsATEX, FM, IEC Ex, NEPSI, EAC
OptionsWeather protection cover
Guide wire assembly
Relief valve
Gas purging nozzle connection
Pressure gauge
Cleaning nozzle connection
SpecialitiesCustody transfer level measurement
Interface measurement
Spot density, density profile measurement
Measuring range36 m (118 ft)
Other approvals and certificatesOIML, NMi, PTB
Returns Policy

Related Products

Top