Endress+Hauser Radiometric Point level detection Gammapilot FTG20

Write a Review

REQUEST A QUOTE

Endress+Hauser Radiometric Point level detection Gammapilot FTG20
Process temperatureAny
Process pressure / max. overpressure limitAny
Min. density of mediumAny
Min. conductivity of mediumAny
Measuring principleRadiometric Limit
Characteristic / ApplicationRadiometric Transmitter with 1 to 3 Geiger-Müller counters for contactless measurement in liquids, sludge or suspensions under exteme process conditions
SpecialitiesCalculation and sizing with Applicator
Supply / CommunicationRelay DPDT:
19...253VAC, 19...55VDC
8/16mA:
11...36VDC, 11..30VDC (Exia)
Ambient temperatureRelay DPDT:
19...253VAC, 19...55VDC
8/16mA:
11...36VDC, 11..30VDC (Exia)
Process temperatureAny
Process pressure / max. overpressure limitAny
Min. density of mediumAny
Min. conductivity of mediumAny
Main wetted partsNon-contact
Process connectionNon-contact
Process connection hygienicNon-contact
Sensor length140 mm (5.5")
CommunicationRelay DPDT
8/16mA
4...20mA
Certificates / ApprovalsATEX, CSA, CSA C/US, IEC Ex, NEPSI, EAC
OptionsSensitivity:
1x Geiger- counter: 1-8uSv/h,
2x Geiger- counter: 0,5-4uSv/h
3x Geiger- counter: 0,3-2,7uSv/h
Cooling jacket
Transmitter with compartment for conduit
ComponentsIsotope: FSG60, FSG61
Source container: FQG60, FQG61, FQG62, FQG63, QG2000
Measuring principleRadiometric Limit
Characteristic / ApplicationRadiometric Transmitter with 1 to 3 Geiger-Müller counters for contactless measurement in solids under exteme process conditions
SpecialitiesCalculation and sizing with Applicator
Supply / CommunicationRelay DPDT:
19...253VAC, 19...55VDC
8/16mA:
11...36VDC, 11..30VDC (Exia)
Ambient temperature-40...70°C,
(-40...158°F),
With cooling jacket:
0...120°C
(32...248°F)
Process temperatureAny
Process pressure / max. overpressure limitAny
Min. density of mediumAny
Main wetted partsNon-contact
Process connectionNon-contact
Process connection hygienicNon-contact
Sensor length140 mm (5.5")
CommunicationRelay DPDT
8/16mA
4...20mA
Certificates / ApprovalsATEX, CSA C/US, IEC Ex, NEPSI, EAC
OptionsSensitivity:
1x Geiger- counter: 1-8uSv/h,
2x Geiger- counter: 0,5-4uSv/h
3x Geiger- counter: 0,3-2,7uSv/h
Cooling jacket
Transmitter with compartment for conduit
ComponentsIsotope: FSG60, FSG61
Source container: FQG60, FQG61, FQG62, FQG63, QG2000
Returns Policy

Related Products

Top