Endress+Hauser Radar measurement Time-of-Flight Micropilot FMR51

Write a Review

REQUEST A QUOTE

Endress+Hauser Radar measurement Time-of-Flight Micropilot FMR51
Accuracy+/- 2 mm (0.08 in)
Process temperatureXT: -196...+280 °C
(-321...+536 °F)
HT: -196...+450 °C
(-321...+842 °F)
Process pressure / max. overpressure limitVacuum...160 bar
(Vacuum...2320 psi)
Max. measurement distanceStandard: 40 m (131 ft)
With "Advanced dynamics": 70 m (230 ft)
Main wetted parts316L, Alloy C, PTFE, ceramic
Measuring principleLevel radar
Characteristic / ApplicationPremium device for continuous non-contact level measurement of liquids, pastes and slurries even under extreme process conditions;
Horn antenna: 40...100 mm
SpecialitiesHeartbeat Technology,
SIL 2 according to IEC 61508,
Bluetooth® commissioning,
Operation and maintenance SmartBlue App,
Safety and reliability with Multi-Echo Tracking,
HistoROM,
RFID TAG for easy identification



Supply / Communication2-wire (HART / PROFIBUS PA/ FOUNDATION Fieldbus)
4-wire (HART)
Bluetooth® wireless technology and App (optional)
FrequencyK-band (~26 GHz)
Accuracy+/- 2 mm (0.08 in)
Ambient temperature-50...+80 °C
(-58...+176 °F)
Process temperatureXT: -196...+280 °C
(-321...+536 °F)
HT: -196...+450 °C
(-321...+842 °F)
Process pressure / max. overpressure limitVacuum...160 bar
(Vacuum...2320 psi)
Main wetted parts316L, Alloy C, PTFE, ceramic
Process connectionThread:
MNPT 1 1/2, R 1 1/2
Flange:
DN50...DN150,
ASME 2"...6",
JIS 10K, 63K
Process connection hygienicTri-Clamp ISO2852
Max. measurement distanceStandard: 40 m (131 ft)
With "Advanced dynamics": 70 m (230 ft)
Communication4...20 mA HART
PROFIBUS PA
FOUNDATION Fieldbus
Bluetooth® wireless technology
Certificates / ApprovalsATEX, FM, CSA C/US, IEC Ex, JPN Ex, INMETRO, NEPSI, KC, EAC, UK Ex
Safety approvalsOverfill protection WHG
SIL
Design approvalsEN 10204-3.1
NACE MR0175, MR0103
ASME B31.3
AD2000
Marine approvalGL/ ABS/ LR/ BV/ DNV
OptionsDisplay,
Customized parameterization,
Remote operation via SmartBlue App using Bluetooth®,
Gas-tight feed through,
Antenna Extension,
PWIS free
Application limitsMaximum measuring range is dependent on the tank form and/or application
Ammoniacal gas phase:
FMR54 in stilling well
Strong build- up formation:
FMR54 with air purge
316L or Alloy C non-resistant:
FMR50, FMR52, FMR53
Hygiene requirements:
FMR52, FMR53
Custody transfer measurement:
FMR5xx