Endress+Hauser RA33 Batch Controller

Write a Review

REQUEST A QUOTE

Endress+Hauser RA33 Batch Controller
Input1 x analogue (I) / pulse (for flow)
1 x RTD (for temperature)
1 x analogue (I) (for density)
Loop power supply 24V DC (+/-16%)
Output1 x analogue (I) / pulse (active)
2 x open collector
Display160 x 80 Dot-Matrix LCD with white backlit
Colour change in case of alarm event
Active display area 70 x 34 mm
CalculationsVolume calculation
Measuring principleApplication manager
Measuring principleBatch controller
FunctionFilling & dosing
CalculationsVolume calculation
Number of applications1
Data storageyes
Calculation standardsASTM D1250-04
CommunicationRS232
USB
Ethernet
Modbus TCP
Modbus RTU



Power supplyNot defined
Loop power supplyLow voltage power supply:
100 bis 230 V AC (-15% / +10%)
Small voltage power supply:
24 V DC (-50% / +75%)
24 V AC (±50%)

Protection classIP65
Input1 x analogue (I) / pulse (for flow)
1 x RTD (for temperature)
1 x analogue (I) (for density)
Loop power supply 24V DC (+/-16%)
Output1 x analogue (I) / pulse (active)
2 x open collector
Dimensions (WxHxD)144 x 144 x 103.1 mm (5.67" x 5.67" x 4.06")
Operation3 operation buttons and 14 function buttons for batch operation or via FieldCare
Read out of historical / logged data via Field Data Manager software (SQL database and visualization interface)
Selectable language
Display160 x 80 Dot-Matrix LCD with white backlit
Colour change in case of alarm event
Active display area 70 x 34 mm
Software functionsVolume calculation
1 or 2 stage operation
Manual and automatic overrun correction
Volume correction factor (VCF) according ASTM D1250-04 for generalized crude oils, refined products and lubricating oils
CertificatesCE
CSA GP
NTEP (USA)
Measuring principleBatch controller
FunctionFilling & dosing
CertificationCE
UL listed
CSA GP
Input1 x analogue (I) / pulse (for flow)
1 x RTD (for temperature)
1 x analogue (I) (for density)
Loop power supply 24V DC (+/-16%)
Output1 x analogue (I) / pulse (active)
2 x open collector
Relay output2 x relay
Auxiliary power supply / Loop power supplyLow voltage power supply:
100 bis 230 V AC (-15% / +10%)
Small voltage power supply:
24 V DC (-50% / +75%), 24 V AC (±50%)
Dimensions (wxhxd)144 x 144 x 103.1 mm
(5.67" x 5.67" x 4.06")
SoftwareVolume calculation
1 or 2 stage operation
Manual and automatic overrun correction
Volume correction factor (VCF) according ASTM D1250-04 for generalized crude oils, refined products and lubricating oils
Operation3 operation buttons and 14 function buttons for batch operation or via FieldCare
Read out of historical / logged data via Field Data Manager software (SQL database and visualization interface)
Selectable language
Display160 x 80 Dot-Matrix LCD with white backlit
Colour change in case of alarm event
Active display area 70 x 34 mm
Returns Policy

Related Products

Top