Max. measurement error | ±0.5% ±0.2% (optional) |
---|---|
Measuring range | 0...110'000 m3/h |
Medium temperature range | -20...+80°C (-4...176°F) |
Max. process pressure | PN6...40 |
Measuring principle | Electromagnetic |
Product headline | The sensor with degree of protection IP68 (Type 6P enclosure) combined with a transmitter for custody transfer. The specialist in the water and wastewater industry for the most demanding applications. |
Sensor features | Secure, reliable long‐term operation – robust and completely welded sensor. Energy‐saving flow measurement – no pressure loss due to cross‐section constriction. Maintenance-free – no moving parts. International drinking water approvals. Degree of protection IP68 (Type 6P enclosure). |
Transmitter features | Quality – designed for custody transfer; featuring worldwide recognized metrological approvals. Safe operation – display provides easy readable process information. Fully industry compliant – IEC/EN/NAMUR. Transmitter certified to MI‐001. Device in compact or remote version. |
Nominal diameter range | DN 25...2000 1"...78" |
Max. measurement error | ±0.5% ±0.2% (optional) |
Measuring range | 0...110'000 m3/h |
Max. process pressure | PN6...40 |
Medium temperature range | -20...+80°C (-4...176°F) |
Ambient temperature range | -20...+60°C -40...+60°C (optional) |
Degree of protection | IP 67 (NEMA 4x) IP 68 (Nema 6P) |
Display/Operation | Two line display with backlit Push button |
Outputs | 4...20 mA Pulse/Frequency Status |
Inputs | Status |
Digital communication | HART |
Hazardous area approvals | ATEX |
Product safety | CE, C-tick, EAC marking |
Metrological approvals and certificates | Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), Custody transfer approvals: MI-001, PTB |
Pressure approvals and certificates | PED |