Process temperature | -20 °C ... 80 °C (-4 °F ... 170 °F) |
---|---|
Process pressure / max. overpressure limit | 0.5 bar to 1.5 bar (7 psi to 22 psi) |
Min. density of medium | >= 100 g/l |
Measuring principle | Paddle |
Characteristic / Application | universally applicable as a full, empty and demand alarm on silos containing solids |
Specialities | Hinged paddle |
Supply / Communication | 230 VAC 50/60 Hz 115 VAC 50/60 Hz 48 VAC 50/60 Hz 24 VAC 50/60 Hz 20 bis 28 VDC |
Ambient temperature | -20 °C ... 60 °C (-4 °F ... 140 °F) |
Process temperature | -20 °C ... 80 °C (-4 °F ... 170 °F) |
Process pressure / max. overpressure limit | 0.5 bar to 1.5 bar (7 psi to 22 psi) |
Min. density of medium | >= 100 g/l |
Main wetted parts | Shaft: 1.4305 Paddle: 1.4301 |
Process connection | G 1 1/2", PBT G 1 1/2", 1.4305 Reinforced shaft G 1 1/2", 1.4305 |
Sensor length | 100 mm (4") 200 mm (8") 300 mm (12") 400 mm (16") 500 mm (20") 600 mm (24") Rope length of approx 2000 mm (80"), can be shortened |
Communication | Micro switch with changeover contact max. 10 A/250 VAC |
Certificates / Approvals | No approvals available |
Options | Relay |
Application limits | max. grain size 50 mm (2") |