Endress+Hauser
Endress+Hauser Multichannel, multiparameter software Memobase Plus CYZ71D
REQUEST A QUOTE
Measuring principle | Potentiometric |
---|---|
Application | Measurement, calibration and documentation of Memosens sensors in laboratories, up to four channels |
Installation | Laboratory or work bench applications in safe area, no connection to PCS! |
Characteristic | Product consists of PC software, USB cable, sensor connection box MemoLink and Memosens lab cable CYK20 optionally, CYK10 with M12 plug can be used alternatively |
Measurement range | Dependent on connected sensors, please see sensor specifications |
Measuring principle | Memosens and measuring principles of the connected sensors |
Material | MemoLink sensor connection box: PBT |
Dimension | MemoLink sensor connection box: 97.0 x 31.5 x 77.5 mm 3.82 x 1.24 x 3.05 inch |
Ex certification | ATEX II (2)G (Ex ia Gb) IIc which enables to connect Ex- and non-ex sensors alternating to the MemoLoink box without loosing the sensor's approval PC, USB cable and MemoLink in safe area only! |
Ingress protection | MemoLink: IP 65 when cables are connected |
Input | Memosens |
Output / communication | USB |
Additional certifications | FDA CFR 21 Part 11 Certificate of compliance when Pharma conformity is ordered |
Measuring principle | Conductive |
Application | Measurement, calibration and documentation of Memosens sensors in laboratories, up to four channels |
Installation | Laboratory or work bench applications in safe area No connection to PCS! |
Characteristic | Product consists of PC software, USB cable, sensor connection box MemoLink and Memosens lab cable CYK20 optionally, CYK10 with M12 plug can be used alternatively |
Measurement range | Dependent on connected sensors, please see sensor specifications |
Measuring principle | Memosens + measuring principles of the connected sensors |
Material | MemoLink sensor connection box: PBT |
Dimension | MemoLink sensor connection box: 97.0 x 31.5 x 77.5 mm 3.82 x 1.24 x 3.05 inch |
Ex certification | ATEX II (2)G (Ex ia Gb) IIc which enables to connect Ex- and non-ex sensors alternating to the MemoLoink box without loosing the sensor's approval PC, USB cable and MemoLink in safe area only! |
Ingress protection | MemoLink: IP 65 when cables are connected |
Input | Memosens |
Output / communication | USB |
Additional certifications | FDA CFR 21 Part 11 Certificate of compliance when Pharma conformity is ordered |
Measuring principle | Amperometric oxygen measurement |
Application | Measurement, calibration and documentation of Memosens sensors in laboratories, up to four channels |
Installation | Laboratory or work bench applications in safe area No connection to PCS! |
Characteristic | Product consists of PC software, USB cable, sensor connection box MemoLink and Memosens lab cable CYK20 optionally, CYK10 with M12 plug can be used alternatively |
Measurement range | Dependent on connected sensors, please see sensor specifications |
Measuring principle | Memosens and measuring principles of the connected sensors |
Material | MemoLink sensor connection box: PBT |
Dimension | MemoLink sensor connection box: 97.0 x 31.5 x 77.5 mm 3.82 x 1.24 x 3.05 inch |
Ex certification | ATEX II (2)G (Ex ia Gb) IIc which enables to connect Ex- and non-ex sensors alternating to the MemoLoink box without loosing the sensor's approval. PC, USB cable and MemoLink in safe area only! |
Ingress protection | MemoLink: IP 65 when cables are connected. |
Input | Memosens |
Output / communication | USB |
Additional certifications | FDA CFR 21 Part 11 Certificate of compliance when Pharma conformity is ordered |
Returns Policy