Endress+Hauser Micropilot FMR67B – 80 GHz radar sensor

Write a Review

REQUEST A QUOTE

Endress+Hauser Micropilot FMR67B – 80 GHz radar sensor
  • Measuring principle

  • Characteristic / Application

  • Specialities

  • Supply / Communication

  • Frequency

  • Accuracy

  • Ambient temperature

  • Process temperature

  • Process pressure / max. overpressure limit

  • Main wetted parts

  • Process connection

  • Max. measurement distance

  • Communication

  • Certificates / Approvals

  • Safety approvals

  • Design approvals

  • Marine approval

  • Options

  • Application limits

  • Accuracy+/-1 mm (0.04 in)
    Process temperature-196 … +450 °C (-321 … +842 °F)
    Process pressure / max. overpressure limitVacuum...160 bar (2320 psi)
    Max. measurement distance80 m (262 ft)
    Main wetted parts316L or PTFE (clad 316L flanges)
    Level radar
    Premium device for continuous non-contact
    level measurements, where aggressive media
    are used; For vessels with many internals
    Heartbeat Technology;
    SIL 2/3 according to IEC 61508;
    Bluetooth® commissioning;
    Operation and maintenance with SmartBlue App;
    HistoROM;
    RFID TAG for easy identification;
    Very narrow beam angle
    2-wire (HART/ PROFIBUS PA)
    PROFINET with Ethernet-APL
    Bluetooth® wireless technology
    W-Band (~80 GHz)
    +/-1 mm (0.04 in)
    -40 … +85 °C (-40 … +185 °F)
    -196 … +450 °C (-321 … +842 °F)
    Vacuum...160 bar (2320 psi)
    316L or PTFE (clad 316L flanges)
    Flange:
    DN50 ... DN150
    ASME 2" ... 8"
    80 m (262 ft)
    HART/ PROFIBUS PA
    PROFINET with Ethernet-APL
    Bluetooth® wireless
    technology and app (optional)
    IEC Ex, ATEX, CSA C/US, EAC Ex, JPN Ex, KC Ex,
    INMETRO Ex, NEPSI Ex, UK Ex
    Overfill protection WHG;
    SIL 2/ SIL 3
    Acceptance test certificate 3.1, EN10204;
    NACE MR0175 / ISO 15156;
    NACE MR0103 / ISO 17945;
    EU Food Contact Material (EC) 1935/2004;
    US Food Contact Material FDA CFR 21;
    Declaration of Conformity ASME B31.3;
    Conformity to cGMP;
    AD2000;
    PMI test;
    CRN approval;
    Helium leak test;
    Liquid penetrant test AD2000-HP5-3(PT);
    Liquid penetrant testing ISO23277-1 (PT);
    Liquid penetrant testing ASME VIII-1 (PT);
    Welding documentation (according to ISO or ASME)
    ABS, LR, BV, RINA, DNV
    Display,
    Customized settings,
    App 'SmartBlue' for commissioning and operation via Bluetooth
    Gas-tight implementation;
    Overvoltage protection;
    PWIS free
    Strong turbulences and foam,
    long stilling wells (>12 m) and bypass -> FMR5x,FMP5x
    Returns Policy