Endress+Hauser
Endress+Hauser Liquiphant FTL64 - reliable detection at high temperatures
REQUEST A QUOTE
Process temperature | -60 °C...+280 °C (-76 °F...+536 °F) |
---|---|
Process pressure / max. overpressure limit | Vacuum...100 bar Vacuum...1450 psi |
Min. density of medium | 0.5 g/cm³ (0.4 g/cm³ optional) |
Measuring principle | Vibration Liquids |
Characteristic / Application | Compact vibronic device for high pressure and high temperature applications, Optional extension tube up to 6 m (19.7 ft), Modular housing concept, Wide range of certificates |
Specialities | Heartbeat Technology, Bluetooth® Operation and maintenance SmartBlue App, LED Module, RFID TAG for easy identification, Second line of defense, Temperature spacer for high process temperature, Plug and play functionalities |
Supply / Communication | 19...253V AC / 2-wire, 10...55V / DC-PNP 3-wire, 9...20V DC with relay DPDT, 19...253V AC or 19...55V DC with relay DPDT, 2-wire NAMUR, 2-wire PFM, 4-20mA HART |
Ambient temperature | -60 °C...+70 °C (-76 °F...+158 °F) |
Process temperature | -60 °C...+280 °C (-76 °F...+536 °F) |
Process pressure / max. overpressure limit | Vacuum...100 bar Vacuum...1450 psi |
Min. density of medium | 0.5 g/cm³ (0.4 g/cm³ optional) |
Main wetted parts | 316L Alloy |
Process connection | Threads: 3/4", 1" Flanges: DN25...DN100 ASME 1"...4" JIS 50A |
Sensor length | up to 6 m (19.7 ft) |
Communication | 2-wire direct load HART DC-PNP 3-wire Relays NAMUR PFM Bluetooth® wireless technology |
Certificates / Approvals | ATEX, IEC Ex, NEPSI, EAC Ex, KC, JPN Ex, INMETRO, UK Ex |
Safety approvals | Overfill protection WHG SIL2/ SIL 3 according to IEC 61508 |
Design approvals | EN 10204-3.1 NACE MR0175, MR0103 ASME B31.3 Process Piping AD2000 CRN |
Marine approval | ABS/ LR/ BV/ DNV |
Options | Ambient temperature down to -60 °C (-76 °F), Heavy duty stainless steel housing, Coating PFA (conductive) |
Components | FTL325P Interface PFM FTL325N Interface NAMUR |