Endress+Hauser iTHERM TM412 Imperial Hygienic Thermometer, US style

Write a Review

REQUEST A QUOTE

Endress+Hauser iTHERM TM412 Imperial Hygienic Thermometer, US style
Accuracyclass B acc. to IEC 60751
class A acc. to IEC 60751
class AA acc. to IEC 60751
Response timedepending on configuration
QuickSens: t90 = 1,5 s
StrongSens: t90 = 9,5 s
Max. process pressure (static)at 20 °C: 40 bar (580 psi)
Operating temperature rangePT100 WW:
-200 °C … 600 °C
(-328 °F … 1.112 °F)
StrongSens:
-50 °C … 500 °C
(-58 °F … 932 °F)
QuickSens:
-50 °C … 200 °C
(-58 °F … 392 °F)
PT100 TF:
-50 °C … 200 °C
(-58 °F … 392 °F)
Max. immersion length on request48"
Measuring principleResistance Temperature Detector
Characteristic / Applicationimperial style
modular temperature assembly
hygienic/aseptic design (3-A®, EHEDG, ASME BPE, FDA)
hygienic process connections
with neck
suitable for hazardous areas
incl. protection tube
QuickSens for fastest response time
StrongSens for most robust design
QuickNeck for easy and cost saving recalibration








Thermowell / protection tubewithout
incl. thermowell
incl. Tee-/elbow thermowell

Insert / probemineral insulated (MI), flexible
pipe version, isolated wires, not flexible
Outer diameter protection tube / Insert1/4'' (6,35 mm)
3/8'' (9,53 mm)
1/2" (12,7 mm)

Max. immersion length on request48"
Material protection tube/ thermowell316L
Process connectionWeld-in adapter
Tri-clamp
Clamp-connections according to ISO2852
G3/4" Liquiphant
G1" Liquiphant
Varivent
T- and elbow thermowell
Tip shapestraight
reduced
Surface roughness Ra30 μin (0,76 μm)
15 μin (0,38 μm )
15 μin (0,38 μm) electropolished
Operating temperature rangePT100 WW:
-200 °C … 600 °C
(-328 °F … 1.112 °F)
StrongSens:
-50 °C … 500 °C
(-58 °F … 932 °F)
QuickSens:
-50 °C … 200 °C
(-58 °F … 392 °F)
PT100 TF:
-50 °C … 200 °C
(-58 °F … 392 °F)
Max. process pressure (static)at 20 °C: 40 bar (580 psi)
Accuracyclass B acc. to IEC 60751
class A acc. to IEC 60751
class AA acc. to IEC 60751
Response timedepending on configuration
QuickSens: t90 = 1,5 s
StrongSens: t90 = 9,5 s
Integration head transmitteryes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)
Ex - approvalsATEX II 3 G Ex nA IIC T6, II3D
CSA General Purpose, CSA C/US
CSA C/US IS, NI I/1+2/A-D
CSA NI I/2/A-D
CSA IS, NI I/1+2/A-D
FM NI I / 2/A-D
FM IS, NI I/1+2/A-D
ATEX IECEx II1G Ex ia IIC T6 Ga
FM+CSA IS, NI I/1+2/A-D
ATEX IECEx II1/2D Ex tb IIIC Da/Db
ATEX IECEx II1/2G Ex ia IIC T6 Ga/Gb
ATEX IECEx II1/2D Ex ia IIIC Da/Db
CertificationSIL (transmitter only)
Returns Policy