Endress+Hauser
Endress+Hauser iTHERM TM402 Imperial Hygienic Thermometer, US style
REQUEST A QUOTE
Accuracy | class A acc. to IEC 60751 |
---|---|
Response time | depending on configuration |
Max. process pressure (static) | at 20 °C: 40 bar (580 psi) |
Operating temperature range | PT100: -50 °C … 200 °C (-58 °F … 392 °F) |
Max. immersion length on request | up to 15.5" (317,5mm) others on request |
Measuring principle | Resistance Temperature Detector |
Characteristic / Application | imperial style hygienic applications aseptic applications hygienic process connections with neck |
Thermowell / protection tube | without (direct immersion) |
Insert / probe | without exchangeable insert |
Outer diameter protection tube / Insert | 1/4'' (6,35 mm) 3/8'' (9,53 mm) |
Max. immersion length on request | up to 15.5" (317,5mm) others on request |
Material protection tube/ thermowell | 316L |
Process connection | Triclamp Clamp-connections according to ISO2852 G3/4" Liquiphant G1" Liquiphant Varivent |
Tip shape | straight reduced |
Surface roughness Ra | 30 μin (0,76 μm) 15 μin (0,38 μm) |
Operating temperature range | PT100: -50 °C … 200 °C (-58 °F … 392 °F) |
Max. process pressure (static) | at 20 °C: 40 bar (580 psi) |
Accuracy | class A acc. to IEC 60751 |
Response time | depending on configuration |
Integration head transmitter | yes (4 ... 20 mA, HART) |
Certification | SIL (transmitter only) |
Returns Policy