Endress+Hauser iTHERM MultiSens Linear TMS11 Multipoint RTD/TC thermometer

Write a Review

REQUEST A QUOTE

Endress+Hauser iTHERM MultiSens Linear TMS11 Multipoint RTD/TC thermometer
Accuracyclass 1 acc. to IEC 60584
class Special ASTM E230 and ANSI MC 96.1
IEC60751 Class A
IEC60751 Class AA
Response timedepending on configuration:
TC:
t50 = 21 s
t90 = 52 s
RTD:
t50 = 42 s
t90 = 108 s
Max. process pressure (static)at 20 °C: 240 bar (3481 psi)
Operating temperature rangeType K:
max. 1.070 °C
(max. 1.958 °F)
Type J:
max. 520 °C
(max. 968 °F)
Type N:
max. 1.100 °C
(max. 2.012 °F)
Pt100 WW:
-200...600 °C
(-328…1.112 °F)
Pt100 TF:
-50…400 °C
(-58…752 °F)
Max. immersion length on requestup to 15.000,00 mm (590'')
Measuring principleResistance Temperature Detector
Characteristic / Applicationmetric style
imperial style
easy-to-use
suitable for hazardous areas
process connection: flanged
light chemical processes
linear sensor distribution
modular design
replaceable sensors during operation







Thermowell / protection tubewith one primary thermowell (for replaceable sensors and increased mechanical protection)
Insert / probemineral insulated (MI) sensors in a primary thermowell
Outer diameter protection tube / Insert48,3mm (1 1/2")
60,3mm (2")
76,1mm (2 1/2")
88,9mm (3")


Max. immersion length on requestup to 15.000,00 mm (590'')
Material protection tube/ thermowell1.4401 (316)
1.4435 (316L)
1.4541 (321)
1.4845 (310L)
1.4301 (304)
1.4307 (304L)




Process connectionflange:
1 1/2 " ASME/ANSI B16.5 150
...900
2" ASME/ANSI B16.5 150
...900
3" ASME/ANSI B16.5 150
..900
DN40 EN/DIN 1092.1 PN10
...PN150
DN50 EN/DIN 1092.1 PN10
...PN150
DN80 EN/DIN 1092.1 PN10
...PN150






Tip shapestraight
Operating temperature rangeType K:
max. 1.070 °C
(max. 1.958 °F)
Type J:
max. 520 °C
(max. 968 °F)
Type N:
max. 1.100 °C
(max. 2.012 °F)
Pt100 WW:
-200...600 °C
(-328…1.112 °F)
Pt100 TF:
-50…400 °C
(-58…752 °F)
Max. process pressure (static)at 20 °C: 240 bar (3481 psi)
Accuracyclass 1 acc. to IEC 60584
class Special ASTM E230 and ANSI MC 96.1
IEC60751 Class A
IEC60751 Class AA
Response timedepending on configuration:
TC:
t50 = 21 s
t90 = 52 s
RTD:
t50 = 42 s
t90 = 108 s
Integration head transmitteryes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)
Ex - approvalsATEX
IECEX
UL
FM
CSA
CertificationSIL (transmitter only)