Endress+Hauser
Endress+Hauser iTHERM MultiSens Linear TMS11 Multipoint RTD/TC thermometer
REQUEST A QUOTE
Accuracy | class 1 acc. to IEC 60584 class Special ASTM E230 and ANSI MC 96.1 IEC60751 Class A IEC60751 Class AA |
---|---|
Response time | depending on configuration: TC: t50 = 21 s t90 = 52 s RTD: t50 = 42 s t90 = 108 s |
Max. process pressure (static) | at 20 °C: 240 bar (3481 psi) |
Operating temperature range | Type K: max. 1.070 °C (max. 1.958 °F) Type J: max. 520 °C (max. 968 °F) Type N: max. 1.100 °C (max. 2.012 °F) Pt100 WW: -200...600 °C (-328…1.112 °F) Pt100 TF: -50…400 °C (-58…752 °F) |
Max. immersion length on request | up to 15.000,00 mm (590'') |
Measuring principle | Resistance Temperature Detector |
Characteristic / Application | metric style imperial style easy-to-use suitable for hazardous areas process connection: flanged light chemical processes linear sensor distribution modular design replaceable sensors during operation |
Thermowell / protection tube | with one primary thermowell (for replaceable sensors and increased mechanical protection) |
Insert / probe | mineral insulated (MI) sensors in a primary thermowell |
Outer diameter protection tube / Insert | 48,3mm (1 1/2") 60,3mm (2") 76,1mm (2 1/2") 88,9mm (3") |
Max. immersion length on request | up to 15.000,00 mm (590'') |
Material protection tube/ thermowell | 1.4401 (316) 1.4435 (316L) 1.4541 (321) 1.4845 (310L) 1.4301 (304) 1.4307 (304L) |
Process connection | flange: 1 1/2 " ASME/ANSI B16.5 150 ...900 2" ASME/ANSI B16.5 150 ...900 3" ASME/ANSI B16.5 150 ..900 DN40 EN/DIN 1092.1 PN10 ...PN150 DN50 EN/DIN 1092.1 PN10 ...PN150 DN80 EN/DIN 1092.1 PN10 ...PN150 |
Tip shape | straight |
Operating temperature range | Type K: max. 1.070 °C (max. 1.958 °F) Type J: max. 520 °C (max. 968 °F) Type N: max. 1.100 °C (max. 2.012 °F) Pt100 WW: -200...600 °C (-328…1.112 °F) Pt100 TF: -50…400 °C (-58…752 °F) |
Max. process pressure (static) | at 20 °C: 240 bar (3481 psi) |
Accuracy | class 1 acc. to IEC 60584 class Special ASTM E230 and ANSI MC 96.1 IEC60751 Class A IEC60751 Class AA |
Response time | depending on configuration: TC: t50 = 21 s t90 = 52 s RTD: t50 = 42 s t90 = 108 s |
Integration head transmitter | yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS) |
Ex - approvals | ATEX IECEX UL FM CSA |
Certification | SIL (transmitter only) |
Returns Policy