Endress+Hauser iTHERM ModuLine TM151

Write a Review

REQUEST A QUOTE

Endress+Hauser iTHERM ModuLine TM151
AccuracyClass AA acc. to IEC 60751
Class A acc. to IEC 60751
Class B acc. to IEC 60751
Class special or standard acc. to ASTM E230
Class 1 or 2 acc. to IEC 60584-2
Response timedepending on configuration
Max. process pressure (static)depending on the configuration up to 500 bar
Operating temperature rangePT100 TF StrongSens:
-50 °C ...500 °C
(-58 °F ...932 °F)
PT100 QuickSensTF:
-50 °C …200 °C
(-58 °F …392 °F)
PT100 WW:
-200 °C ...600 °C
(-328 °F ...1.112 °F)
PT100 TF:
-50 °C ...400 °C
(-58 °F ...752 °F)
Typ K:
max. 1.100 °C
(max. 2.012 °F)
Typ J:
max. 800 °C
(max. 1.472 °F)
Typ N:
max. 1.100 °C
(max. 2.012 °F)
Max. immersion length on requestup to 1.500,0 mm (59,06'')
Measuring principleResistance Temperature Detector
Characteristic / Applicationmetric style
modular temperature assembly
universal range of application
suitable for hazardous areas
suitable for high process pressures
with neck or QuickNeck
incl. thermowell / protection tube (metal) or to be installed into thermowell
can be used with StrongSens






Thermowell / protection tubebarstock (drilled) or to be used with thermowell
Insert / probemineral insulated (MI), flexible
Outer diameter protection tube / Insert16 mm (0,63")
18 mm (0,71")
19 mm (0,75")
19,5 mm (0,77")
20 mm (0,79")
22,2 mm (0,87")
24 mm (0,95")
25 mm (0,98")
25,4 mm (1,0")
26 mm (1,02")
27 mm (1,06")
30 mm (1,18")
33,4 mm (1,31")











Max. immersion length on requestup to 1.500,0 mm (59,06'')
Material protection tube/ thermowell316 (1.4401)
316L (1.4404)
316/316L (1.4401/1.4404)
316Ti (1.4571)
347 (1.4550)
310 (1.4841)
Alloy 600 (2.4816)
Alloy C276 (2.4819)
10CrMo9-10 (1.7380)
13CrMo4-5 (1.7335)
16Mo3 (1.5415)
A105 (1.0460)
C22.8 (P250GH) (1.0460)
P355NH (1.0565)
Duplex S32205 (1.4462)
Titanium Gr2 (3.7035)




Process connectionMale thread:
G1"
NPT1/2", NPT3/4", NPT 1"
M14x1.5, M18x1.5, M20x1.5, M27x2, M33x2
Female thread:
M24x1.5
NPT1/2"
Flange:
DN25 PN16, PN40, PN50, PN100 B1
DN40 PN40 B1
DN50 PN40, PN63 B1
ASME 1" 150 RF
ASME 1" 300 RF
ASME 1" 600 RF
ASME 1" 900/1500 RF
ASME 1 1/2" 150 RF
ASME 1 1/2" 300 RF
ASME 1 1/2" 600 RF
ASME 1 1/2" 900/1500 RF
ASME 1 1/2" 2500 RF
ASME 2" 150 RF
ASME 2" 300 RF
ASME 2" 600 RF
ASME 2" 900/1500 RF
ASME 2" 2500 RF
to weld-in:
Diameter 18 mm (0,71")
Diameter 24 mm (0,94")
Diameter 26 mm (1,02")
Diameter 26,7 mm (NPS 3/4")
Diameter 33,4 mm (NPS 1")
Tip shapestraight
tapered
stepped
Surface roughness Ra0,76 μm (30 μin.)
1,6 μm (63,0 μin.)
Operating temperature rangePT100 TF StrongSens:
-50 °C ...500 °C
(-58 °F ...932 °F)
PT100 QuickSensTF:
-50 °C …200 °C
(-58 °F …392 °F)
PT100 WW:
-200 °C ...600 °C
(-328 °F ...1.112 °F)
PT100 TF:
-50 °C ...400 °C
(-58 °F ...752 °F)
Typ K:
max. 1.100 °C
(max. 2.012 °F)
Typ J:
max. 800 °C
(max. 1.472 °F)
Typ N:
max. 1.100 °C
(max. 2.012 °F)
Max. process pressure (static)depending on the configuration up to 500 bar
AccuracyClass AA acc. to IEC 60751
Class A acc. to IEC 60751
Class B acc. to IEC 60751
Class special or standard acc. to ASTM E230
Class 1 or 2 acc. to IEC 60584-2
Response timedepending on configuration
Integration head transmitteryes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)
Ex - approvalsATEX II3G Ex nA IIC T6, II3D
CSA C/US General Purpose
CSA C/US IS, NI I/1+2/A-D
CSA C/US XP, NI, DIP I, II, III/1+2/A-G
CSA C/US DIP II, III / 1/E-G
EAC 0Ex ia IIC T6...T1 Ga X
EAC Ga/Gb Ex d IIC T6...T1 X
EAC Ex ta/tb IIIC 85oC...450oC Da/Db X
EAC Ga/Gb Ex ia IIC T6...T1 X
EAC 0Ex ia IIC T6...T1 Ga X, Ex ia IIIC 85oC...450oC Da/Db X
EAC Ga/Gb Ex d IIC T6...T1 X, Ex ta/tb IIIC 85oC...450oC Da/Db X
INMETRO Ex ia IIC T6 Ga/Gb, Ex ia IIIC Da/Db
INMETRO Ex d IIC T6 Ga/Gb, Ex tb IIIC Da/Db
INMETRO Ex nA IIC T6 Gc
CCC Ex ia IIC T6 Ga/Gb
CCC Ex d IIC T6 Ga/Gb, Ex tD A20/A21
CCC Ex tD A20/A21
CCC Ex nA IIC T6 Gc
UK II1/2G Ex ia IIC T6 Ga/Gb, II1/2D Ex ia IIIC Da/Db
UK II3G Ex nA IIC T6 Gc, II3D Ex tc IIIC Dc
UK II1/2G Ex db IIC T6 Ga/Gb, II1/2D Ex ta/tb IIIC Da/Db
ATEX IECEx II1/2D Ex ta/tb IIIC Da/Db
ATEX IECEx II1/2G Ex ia IIC T6 Ga/Gb
ATEX IECEx II1/2G Ex ia IIC T6, II1/2D
ATEX IECEx II1/2G Ex db IIC T6, II1/2D
CertificationSIL, MID, DNV/GL
Returns Policy