Endress+Hauser iTHERM ModuLine TM121

Write a Review

REQUEST A QUOTE

Endress+Hauser iTHERM ModuLine TM121
AccuracyClass A acc. to IEC 60751
Class B acc. to IEC 60751
Class standard acc. to ASTM E230
Class 2 acc. to IEC 60584-2
Response timet90 around 100 s
depending on configuration
Max. process pressure (static)depending on the configuration
Operating temperature rangeBasic PT100 TF:
-50 °C …200 °C
(-58 °F …392 °F)
Typ K:
max. 1.100 °C
(max. 2.012 °F)
Max. immersion length on requestup to 1.000,0 mm (39'')
Measuring principleResistance Temperature Detector
Characteristic / Applicationmetric style
modular temperature assembly
universal range of application
with neck
incl. thermowell / protection tube (metal)



Thermowell / protection tubewelded protection tube or to be used with thermowell
Insert / probeBasis Sensortechnologie
Outer diameter protection tube / InsertThermowell:
9x1,25 mm
11x2 mm

Max. immersion length on requestup to 1.000,0 mm (39'')
Material protection tube/ thermowell316L (1.4404)
Process connectionThread:
G1/2"
NPT1/2"
M20x1.5, M27x2, M33x2
Compression fitting:
NPT1/2", G1/2", G1"
Flansche:
DN25 DN40 B1
ASME 1" 150 RF
ASME 1" 300 RF
ASME 1 1/2" 150 RF
ASME 2" 150 RF
ASME 2" 300 RF


Tip shapestraight
Operating temperature rangeBasic PT100 TF:
-50 °C …200 °C
(-58 °F …392 °F)
Typ K:
max. 1.100 °C
(max. 2.012 °F)
Max. process pressure (static)depending on the configuration
AccuracyClass A acc. to IEC 60751
Class B acc. to IEC 60751
Class standard acc. to ASTM E230
Class 2 acc. to IEC 60584-2
Response timet90 around 100 s
depending on configuration
Integration head transmitteryes (4 … 20 mA; HART)