Endress+Hauser
Endress+Hauser Hydrostatic Level measurement Deltapilot FMB70
REQUEST A QUOTE
Accuracy | Standard 0.1% Optional 0.075% |
---|---|
Process temperature | -10°C...+100°C (+14°F...+212°F) |
Pressure measuring range | 100 mbar...10 bar (1.5 psi...150 psi) |
Process pressure / max. overpressure limit | 40 bar (600 psi) |
Main wetted parts | Alloy C 316L |
Max. measurement distance | 100 m (328 ft) H2O |
Material process membrane | 316L, AlloyC, Gold-Rhodium |
Measuring cell | 100 mbar...10 bar (1.5 psi...150 psi) |
Measuring principle | Hydrostatic pressure |
Characteristic | Pressure transmitter for hydrostatic level measurement with flush mounted metallic Contite measuring cell: Hermetically sealed, condensate-resistant, climatic-proofed and with lowest temperature influences Compact version |
Supply voltage | 4...20 mA HART 10,5...45 VDC (Non Ex): Ex ia: 10,5...30 VDC PROFIBUS PA: 9...32 VDC (Non Ex) FOUNDATION Fieldbus: 9...32 VDC (Non Ex) |
Reference Accuracy | Standard 0.1% Optional 0.075% |
Long term stability | 0.05 % of URL/year |
Process temperature | -10°C...100°C (14°F...212°F) |
Ambient temperature | -40°C...85°C (-40°F...185°F) |
Measuring cell | 100 mbar...10 bar (1.5 psi...150 psi) |
Smallest calibratable span | 25 mbar (3.63 psi) |
Vacuum resistance | 0 mbar abs. |
Max. overpressure limit | 40 bar (600 psi) |
Process connection | Thread: G1 1/2, MNPT1/2 Flange: DN40...DN100, ASME 1 1/2"...4", JIS 10K |
Process connection hygienic | Tri-Clamp DIN11851 DIN11864-1 NEUMO Varivent N SMS DRD |
Material process membrane | 316L, AlloyC, Gold-Rhodium |
Material gasket | None, measuring cell welded |
Fill fluid | Inert oil, Synthetic oil |
Material housing | 316L, Die-cast aluminum |
Communication | 4 ... 20 mA HART PROFIBUS PA FOUNDATION Fieldbus |
Certificates / Approvals | ATEX, FM, CSA, CSA C/US, IEC Ex, INMETRO, NEPSI, EAC, UK Ex |
Safety approvals | SIL |
Design approvals | EN10204-3.1 NACE MR0175 MR0103 |
Hygienic approvals | 3A, EHEDG CoC ASME-BPE |
Marine approvals | GL, DNV |
Drinking water approvals | NSF |
Specialities | Gold-rhodium coated membrane |
Measuring principle | Hydrostatic |
Characteristic / Application | Compact pressure transmitter for hydrostatic level measurement with flush mounted metallic Contite measuring cell: Hermetically sealed, condensate-resistant and climatic-proofed |
Specialities | Diagnostic functions |
Supply / Communication | 4...20mA HART: 10,5...45V DC Ex ia: 10,5...30V DC PROFIBUS PA / FOUNDATION Fieldbus: 9...32V DC (Non Ex) |
Accuracy | Standard 0.1% Optional 0.075% |
Long term stability | 0.05 % of URL/year |
Ambient temperature | -40°C...+85°C (-40°F...+185°F) |
Process temperature | -10°C...+100°C (+14°F...+212°F) |
Process pressure / max. overpressure limit | 40 bar (600 psi) |
Pressure measuring range | 100 mbar...10 bar (1.5 psi...150 psi) |
Main wetted parts | Alloy C 316L |
Process connection | Thread: G1 1/2, MNPT1/2 Flange: DN40...DN100, ASME 1 1/2"...4", JIS 10K |
Process connection hygienic | Tri-Clamp DIN11851 DIN11864-1 NEUMO Varivent N SMS DRD |
Max. measurement distance | 100 m (328 ft) H2O |
Communication | 4...20 mA HART PROFIBUS PA FOUNDATION Fieldbus |
Certificates / Approvals | ATEX, FM, CSA, CSA C/US, IEC Ex, INMETRO, NEPSI, EAC |
Safety approvals | SIL |
Design approvals | EN10204-3.1 NACE MR0175, MR0103 |
Hygienic approvals | 3A, EHEDG CoC ASME-BPE |
Marine approval | GL/ DNV |
Drinking water approvals | NSF |
Options | HistoROM/M-Dat 4-line digital display SS- or Aluminiumhousing Separate housing |
Application limits | Measuring cell: Contite, condensate-proof, watertight, metal welded If pressurized, possibly use differential pressure measurement with two pressure transmitters. Observe ratio head pressure : hydrostatic pressure |
Returns Policy