Endress+Hauser
Endress+Hauser Hydrostatic Level measurement Deltapilot FMB52
REQUEST A QUOTE
Accuracy | Standard 0.2% Optional 0.1% |
---|---|
Process temperature | PE cable: -10°C…70°C / 14°F…158°F FEP cable: -10°C…80°C / 14°F…176°F |
Pressure measuring range | 100 mbar...10 bar (1.5 psi...150 psi) |
Process pressure / max. overpressure limit | 40 bar (600 psi) |
Main wetted parts | Alloy C 316L Cable (PE/FEP) optional coating AuPt optional coating AuRh |
Max. measurement distance | 100 m (328 ft) H2O |
Material process membrane | 316L, AlloyC, Gold-Rhodium PE, FEP |
Measuring cell | 100 mbar...10 bar (1.5 psi...150 psi) |
Measuring principle | Hydrostatic pressure |
Characteristic | Pressure transmitter for hydrostatic level measurement with flush mounted metallic Contite measuring cell: Hermetically sealed, condensate-resistant, climatic-proofed and with lowest temperature influences Cable version |
Supply voltage | 4...20 mA HART 10,5...45 VDC (Non Ex): Ex ia: 10,5...30 VDC PROFIBUS PA: 9...32 VDC (Non Ex) FOUNDATION Fieldbus: 9...32 VDC (Non Ex) |
Reference Accuracy | Standard 0.2% Optional 0.1% |
Long term stability | 0.05 % of URL/year |
Process temperature | PE cable: -10°C…70°C / 14°F…158°F FEP cable: -10°C…80°C / 14°F…176°F |
Ambient temperature | -40°C...85°C (-40°F...185°F) |
Measuring cell | 100 mbar...10 bar (1.5 psi...150 psi) |
Smallest calibratable span | 10 mbar (1.45 psi) |
Vacuum resistance | 0 mbar abs. |
Max. Turn down | 100:1 |
Max. overpressure limit | 40 bar (600 psi) |
Process connection | Thread: G1 1/2, MNPT1 1/2 Flange: DN40...DN100, ASME 2"...4", JIS 10K |
Material process membrane | 316L, AlloyC, Gold-Rhodium PE, FEP |
Material gasket | Viton, EPDM, Kalrez, none |
Fill fluid | Inert oil, Synthetic oil |
Material housing | 316L, Die-cast aluminum |
Communication | 4...20 mA HART PROFIBUS PA FOUNDATION Fieldbus |
Certificates / Approvals | ATEX, FM, CSA, CSA C/US, IEC Ex, INMETRO, NEPSI, UK Ex |
Safety approvals | Overfill protection WHG SIL |
Design approvals | EN10204-3.1 NACE MR0175 |
Marine approvals | GL/ ABS/ LR/ BV/ DNV |
Drinking water approvals | KTW/ NSF/ ACS |
Specialities | Modularity to differential pressure and process pressure devices (replacable display, universal electronics) Diagnostic functions |
Measuring principle | Hydrostatic |
Characteristic / Application | Pressure transmitter for hydrostatic level measurement with flush mounted metallic Contite measuring cell: Hermetically sealed, condensate-resistant and climatic-proofed Cable version |
Specialities | Modularity to differential pressure and process pressure devices (replacable display, universal electronics) diagnostic functions Hermetically sealed Contite measuring cell (condensate-resistant and climatic-proofed) |
Supply / Communication | 4...20mA HART: 10,5...45V DC Ex ia: 10,5...30V DC PROFIBUS PA / FOUNDATION Fieldbus: 9...32V DC (Non Ex) |
Accuracy | Standard 0.2% Optional 0.1% |
Long term stability | 0.05 % of URL/year |
Ambient temperature | -40°C...85°C (-40°F...185°F) |
Process temperature | PE cable: -10°C…70°C / 14°F…158°F FEP cable: -10°C…80°C / 14°F…176°F |
Process pressure / max. overpressure limit | 40 bar (600 psi) |
Pressure measuring range | 100 mbar...10 bar (1.5 psi...150 psi) |
Main wetted parts | Alloy C 316L Cable (PE/FEP) optional coating AuPt optional coating AuRh |
Process connection | Thread: G1 1/2, MNPT1 1/2 Flange: DN40...DN100, ASME 2"...4", JIS 10K |
Max. measurement distance | 100 m (328 ft) H2O |
Communication | 4...20 mA HART PROFIBUS PA FOUNDATION Fieldbus |
Certificates / Approvals | ATEX, FM, CSA, CSA C/US, IEC Ex, INMETRO, NEPSI |
Safety approvals | Overfill protection WHG SIL |
Design approvals | EN10204-3.1 NACE MR0175 |
Marine approval | GL/ ABS/ LR/ BV/ DNV |
Drinking water approvals | KTW/ NSF/ ACS |
Options | Separate housing Initial device settings Overvoltage protection |
Application limits | If pressurized, usage of two pressure transmitters to measure the differential pressure (electronic dP) Observe ratio head pressure : hydrostatic pressure In case of an open tank or shaft use FMB53 with mounting clamp. |
Returns Policy