Endress+Hauser
Endress+Hauser Field Xpert SMT70
REQUEST A QUOTE
Input | Camera: • 5 MP camera on the back with auto focus and LED flash with 1500 mcd • 2 MP camera on the front Scanner: • 1D/2D barcode scanner |
---|---|
Measuring principle | Device configurator |
Function | The Field Xpert SMT70 tablet PC for universal device configuration supports protocols such as HART, PROFIBUS DP/PA, FOUNDATION Fieldbus, Modbus, and Endress+Hauser service protocols (CDI, ISS, IPC and PCP). The devices can be connected directly via a suitable interface e.g. a modem (point-to-point) or a bus system (point-to-bus). |
Input | Camera: • 5 MP camera on the back with auto focus and LED flash with 1500 mcd • 2 MP camera on the front Scanner: • 1D/2D barcode scanner |
CPU | Intel Core i5-5200U (2,2...2,7 GHz) |
Memory | • 8 GB with DDR3L adapter • 256 GB SSD M2-SATA robust version • Micro SD card slot, support for SDHC/SDXC |
Power supply | Replaceable, rechargeable lithium polymer battery, 11.1 VDC, 4100 mAh (45 Wh)/7800 mAh (86 Wh) (optional) |
Dimensions (WxHxD) | 298.5 mm x 192 mm x 20 mm (11.4 in x 7.48 in x 0.78 in) |
Screen size | • 11.6" LCD display, with Gorilla Glass protector • Capacitive multi-touch screen • Optical bonding, sunlight readable, LCD (730 Nit) • Ambient light sensor |
Resolution | 1366 x 768 pixels |
Communication interface | • 2 x USB 3.0 • Intel Wireless AC7260 802.11 a/b/g/n/ac, DUAL Band WLAN • Bluetooth 4.0 BLE, Class 1 • 4G LTE WWAN + 12 channel GPS (optional) |
Operation | Operating system: Windows 10 IoT Enterprise |
Configuration | Touch-enabled device configuration software optimized for Field Xpert. The software supports protocols such as HART, PROFIBUS DP/PA, FOUNDATION Fieldbus, Modbus, and Endress+Hauser service protocols (CDI, ISS, IPC and PCP) and includes more than 2,700 pre-installed device and communication drivers. |
Optional | 4G LTE WWAN + 12 channel GPS |
Certificates | Degree of protection: • IP65 Shock resistance: • MIL-STD 810G 516.6 Procedure IV Electromagnetic Compatibility: Interference conformance to • EN 55022: 2010+ AC: 2011 • EN 55022 Class B • EN 61000-3-2 • EN 61000-3-3 Interference immunity to • EN 55024: 2010 • IEC 61000-4-2 • IEC 61000-4-3 • IEC 61000-4-4 • IEC 61000-4-5 • IEC 61000-4-6 • IEC 61000-4-8 • IEC 61000-4-11 Hazardous area approval: ATEX (Europe) • ATEX II 3G Ex ic IIC T4 Gc IP64 • ATEX II 3D Ex ic IIIB T135°C Dc IP 64 NEC/CEC (North America) • NEC/CEC Class 1, Div. 2, Group A-D T4 • NEC/CEC Class 1, Zone 2, Group IIC T4 IECEx (International) • IECEx Ex ic IIC T4 Gc IP64 • IECEx Ex ic IIIB T135° Dc IP64 Radio approval: • CE, FCC, IC |
Returns Policy