Max. measurement error | Volume flow: +/-0.8% o.r. +/- 0.1% o.f.s |
---|---|
Measuring range | up to 750 l/min |
Medium temperature range | -10 to 70°C (+14 to +158 °F) Permissible short-term temperature, maximum one hour: 85 °C (185 °F) Repetition after 4 hours at the earliest |
Max. process pressure | 16 bar |
Wetted materials | PEEK, Stainless Steel, FKM, EPDM Electrodes: 1.4404/316L |
Measuring principle | Electromagnetic |
Product headline | Smart magmeter for utilities – intuitive · convenient · multivariable. Time-saving, easy configuration even in places difficult to reach – secure Bluetooth connection. Ideal for process quality control and monitoring due to temperature and conductivity measurement in utilities. |
Sensor features | Fewer measuring points necessary – simultaneous flow, conductivity and temperature measurement. Cost-efficient specialist for use in tight spaces e.g. skids – sensor and transmitter in one housing. High shock and vibration resistance. Degree of protection: IP65/67. Empty pipe detection. |
Transmitter features | Quick offline configuration check – unique, comfortable knock functionality. Simple device access through its whole lifecycle – no manual needed due to intuitive SmartBlue app. Effortless configuration of several devices – settings can be saved and loaded into other meters. Flexible integration into all fieldbus systems – plug-and-play device with IO-Link. Wireless remote access via Bluetooth SmartBlue app. IO-Link and various I/Os for all line-sizes. 1.4" TFT color display with backlight. |
Nominal diameter range | DN15 to 50 (1/2 to 2") |
Wetted materials | PEEK, Stainless Steel, FKM, EPDM Electrodes: 1.4404/316L |
Measured variables | Volume flow, Temperature, Conductivity |
Max. measurement error | Volume flow: +/-0.8% o.r. +/- 0.1% o.f.s |
Measuring range | up to 750 l/min |
Max. process pressure | 16 bar |
Medium temperature range | -10 to 70°C (+14 to +158 °F) Permissible short-term temperature, maximum one hour: 85 °C (185 °F) Repetition after 4 hours at the earliest |
Ambient temperature range | -10 to 60 °C |
Sensor housing material | 1.4404/316L, Polycarbonate |
Transmitter housing material | 1.4404/316L, Polycarbonate |
Degree of protection | IP 65/67 |
Display/Operation | Integrated display, operation via SmartBlue app |
Outputs | Current (4 to 20mA) Pulse Switch Voltage (2 to 10V) |
Inputs | Status |
Digital communication | IO-Link |
Power supply | 18 to 30V DC |
Product safety | cULus listing |
Hygienic approvals and certificates | Drinking water approvals: NSF |