Endress+Hauser DMA Picomag electromagnetic flowmeter

Write a Review

REQUEST A QUOTE

Endress+Hauser DMA Picomag electromagnetic flowmeter
Max. measurement errorVolume flow: +/-0.8% o.r. +/- 0.1% o.f.s
Measuring rangeup to 750 l/min
Medium temperature range-10 to 70°C (+14 to +158 °F)
Permissible short-term temperature, maximum one hour:
85 °C (185 °F)
Repetition after 4 hours at the earliest
Max. process pressure16 bar
Wetted materialsPEEK, Stainless Steel, FKM, EPDM
Electrodes: 1.4404/316L
Measuring principleElectromagnetic
Product headlineSmart magmeter for utilities – intuitive · convenient · multivariable.
Time-saving, easy configuration even in places difficult to reach – secure Bluetooth connection.
Ideal for process quality control and monitoring due to temperature and conductivity measurement in utilities.

Sensor featuresFewer measuring points necessary – simultaneous flow, conductivity and temperature measurement. Cost-efficient specialist for use in tight spaces e.g. skids – sensor and transmitter in one housing.
High shock and vibration resistance. Degree of protection: IP65/67. Empty pipe detection.
Transmitter featuresQuick offline configuration check – unique, comfortable knock functionality. Simple device access through its whole lifecycle – no manual needed due to intuitive SmartBlue app. Effortless configuration of several devices – settings can be saved and loaded into other meters. Flexible integration into all fieldbus systems – plug-and-play device with IO-Link.
Wireless remote access via Bluetooth SmartBlue app. IO-Link and various I/Os for all line-sizes. 1.4" TFT color display with backlight.
Nominal diameter rangeDN15 to 50 (1/2 to 2")
Wetted materialsPEEK, Stainless Steel, FKM, EPDM
Electrodes: 1.4404/316L
Measured variablesVolume flow, Temperature, Conductivity
Max. measurement errorVolume flow: +/-0.8% o.r. +/- 0.1% o.f.s
Measuring rangeup to 750 l/min
Max. process pressure16 bar
Medium temperature range-10 to 70°C (+14 to +158 °F)
Permissible short-term temperature, maximum one hour:
85 °C (185 °F)
Repetition after 4 hours at the earliest
Ambient temperature range-10 to 60 °C
Sensor housing material1.4404/316L, Polycarbonate
Transmitter housing material1.4404/316L, Polycarbonate
Degree of protectionIP 65/67
Display/OperationIntegrated display, operation via SmartBlue app
OutputsCurrent (4 to 20mA)
Pulse
Switch
Voltage (2 to 10V)
InputsStatus
Digital communicationIO-Link
Power supply18 to 30V DC
Product safetycULus listing
Hygienic approvals and certificatesDrinking water approvals: NSF
Returns Policy

Related Products

Top