Endress+Hauser Digital service and qualification tool Memocheck Sim CYP03D

Write a Review

REQUEST A QUOTE

Endress+Hauser Digital service and qualification tool Memocheck Sim CYP03D
Measuring principlePotentiometric
ApplicationSimulation of freely configurable values for qualification of digital data transmission of analysis measuring points with Memosens protocol
Multiparameter, main- and secondary values
InstallationTemporary connection via Memosens cable with inductive coupling
Measurement rangeRanges like the simulated sensors
DimensionHandheld:
94 x 236 x 40 mm
3.7 x 9.29 x 1.57 inch
Process temperatureAmbient temperature: –20 to 50 °C (–4 to 120 °F)
Ex certificationATEX, IECEx, CSA
ConnectionBattery powered
Ingress protectionIP65
Measuring principleSensor ORP / Redox
ApplicationSimulation of freely configurable values for qualification of digital data transmission of analysis measuring points with Memosens protocol
Multiparameter, main- and secondary values
InstallationTemporary connection via Memosens cable with inductive coupling
Measurement rangeRanges like the simulated sensors
DimensionHandheld:
94 x 236 x 25 to 40 mm
3.7 x 9.29 x 0.98 to 1.57 inch
Process temperatureAmbient temperature: –20 to 50 °C (–4 to 120 °F)
Ex certificationATEX, IECEx, CSA
ConnectionBattery powered
Ingress protectionIP65
Measuring principleConductive
ApplicationSimulation of freely configurable values for qualification of digital data transmission of analysis measuring points with Memosens protocol
Multiparameter, main- and secondary values
InstallationTemporary connection via Memosens cable with inductive coupling
Measurement rangeRanges like the simulated sensors
DimensionHandheld:
94 x 236 x 25 to 40 mm
3.7 x 9.29 x 0.98 to 1.57 inch
Process temperatureUmgebungstemperatur: –20 to 50 °C (–4 to 120 °F)
Ex certificationATEX, IECEx, CSA
ConnectionBattery powered
Ingress protectionIP65
Measuring principleAmperometric oxygen measurement
ApplicationSimulation of freely configurable values for qualification of digital data transmission of analysis measuring points with Memosens protocol
Multiparameter, main- and secondary values
InstallationTemporary connection via Memosens cable with inductive coupling
Measurement rangeRanges like the simulated sensors
DimensionHandheld:
94 x 236 x 25 to 40 mm
3.7 x 9.29 x 0.98 to 1.57 inch
Process temperatureAmbient temperature: –20 to 50 °C (–4 to 120 °F)
Ex certificationATEX: Ex ia, zone 0
ConnectionBattery powered
Ingress protectionIP65
Measuring principleFree chlorine
ApplicationSimulation of freely configurable values for qualification of digital data transmission of analysis measuring points with Memosens protocol
Multiparameter, main- and secondary values
Measurement rangeRanges like the simulated sensors
DimensionHandheld:
94 x 236 x 25 to 40 mm
3.7 x 9.29 x 0.98 to 1.57 inch
Process temperatureAmbient temperature: –20 to 50 °C (–4 to 120 °F)
ConnectionBattery powered
Measuring principleSingle beam scattered light
ApplicationSimulation of freely configurable values for qualification of digital data transmission of analysis measuring points with Memosens protocol.
Multiparameter, main- and secondary values
InstallationTemporary connection via Memosens cable with inductive coupling.
Measurement rangeRanges like the simulated sensors.
DimensionHandheld, 9,5 x 23,5 x 3,5 cm
Process temperature-20...55°C ambient temperature
Ex certificationATEX: Ex ia, zone 1
ConnectionBattery powered
Ingress protectionIP65
Returns Policy