Endress+Hauser
Endress+Hauser Digital nitrate or SAC sensor Viomax CAS51D
REQUEST A QUOTE
Measurement range | 0.01 to 20 mg/l / 0.1 to 50 mg/l NO3-N 0.04 to 80 mg/l / 0.4 to 200 mg/l NO3 0 to 50 1/m / 0 to 250 1/m / 0 to 1000 1/m SAC 0 to 75 mg/l / 0 to 375 mg/l / 0 to 1500 mg/l COD/BOD (254nm) 0 to 30 mg/l / 0 to 150 mg/l / 0 to 600 mg/l TOC/DOC (254nm) |
---|---|
Process temperature | 5 to 50°C (41 to 120 °F) |
Measuring principle | UV photometric |
Characteristic | Insitu (immersion in process), extractive with sample and flow cell Optical photometric sensor for nitrate and SAC |
Size | 388 / 394 mm x 40 mm, depends on version |
Design | 40 mm sensor, stainless steel 316L |
Process temperature | 5 to 50°C (41 to 120 °F) |
Ambient temperature | -20 to 60 °C (-4 to 140 °F) |
Specials | G1, NPT3/4 IP68 (1m/3,3ft) water column with 1N KCl during 60d ays |
Application | Drinking water, biological waste wate process, WWTP effluent Monitoring of surface water |
Measurement range | 0.01 to 20 mg/l / 0.1 to 50 mg/l NO3-N 0.04 to 80 mg/l / 0.4 to 200 mg/l NO3 0 to 50 1/m / 0 to 250 1/m / 0 to 1000 1/m SAC 0 to 75 mg/l / 0 to 375 mg/l / 0 to 1500 mg/l COD/BOD (254nm) 0 to 30 mg/l / 0 to 150 mg/l / 0 to 600 mg/l TOC/DOC (254nm) |