Endress+Hauser
Endress+Hauser Digital measuring cable CYK20
REQUEST A QUOTE
Measuring principle | Potentiometric |
---|---|
Application | Laboratory Measuring cable for contactless, inductive, digital transmission of measurement signals |
Installation | Inductive plug-head for digital sensors with Memosens technology and M8 or M12 plug to connect to the transmitter. |
Characteristic | Inductive, digital transmission of measurement signals and energy. Not influenced by moisture, EMC-field and corrosion. |
Design | Easy to handle Bajonett coupling to connect digital sensors with Memosens technology and plug-head. No open contacts, resistant against huminity. |
Material | PEEK / TPE |
Dimension | Diameter: 4.5 mm ( 0.18" ) Cores: 2x2 cores, twisted paires Length: 1.5 m +3 m (4.9 ft+ 9.8 ft ) |
Ex certification | IECEX EX ia II C T6 Ga ATEX EX II 1G Ex ia II C T6 Ga |
Ingress protection | IP 65 |
Measuring principle | Conductive |
Application | Laboratory measuring cable for contactless, inductive, digital transmission of measurement signals |
Installation | Inductive plug-head for digital sensors with Memosens technology and M8 or M12 plug to connect to the transmitter. |
Characteristic | Inductive, digital transmission of measurement signals and energy. Not influenced by moisture, EMC-field and corrosion. |
Design | Easy to handle Bajonett coupling to connect digital sensors with Memosens technology and plug-head. No open contacts, resistant against huminity. |
Dimension | Diameter: 4.5 mm ( 0.18" ) Cores: 2x2 cores, twisted paires Length: 1.5 m +3 m (4.9 ft+ 9.8 ft ) |
Ex certification | IECEX EX ia II C T6 Ga ATEX EX II 1G Ex ia II C T6 Ga |
Ingress protection | IP65 |
Measuring principle | Amperometric oxygen measurement |
Application | Laboratory measuring cable for contactless, inductive, digital transmission of measurement signals |
Installation | Inductive plug-head for digital sensors with Memosens technology and M8 or M12 plug to connect to the transmitter. |
Characteristic | Inductive, digital transmission of measurement signals and energy. Not influenced by moisture, EMC-field and corrosion. |
Design | Easy to handle Bajonett coupling to connect digital sensors with Memosens technology and plug-head. No open contacts, resistant against huminity. |
Dimension | Diameter: 4.5 mm ( 0.18" ) Cores: 2x2 cores, twisted paires Length: 1.5 m +3 m (4.9 ft+ 9.8 ft ) |
Ex certification | IECEX EX ia II C T6 Ga ATEX EX II 1G Ex ia II C T6 Ga |
Connection | IP65 |
Returns Policy