Endress+Hauser
Endress+Hauser Digital measuring cable CYK10
REQUEST A QUOTE
Measuring principle | Potentiometric |
---|---|
Application | Measuring cable for contactless, inductive, digital transmission of measurement signals |
Installation | Inductive plug- head for digital sensors with Memosens technology and wire terminals or M12 plug to connect to the transmitter |
Characteristic | Inductive, digital transmission of measurement signals and energy Not influenced by moisture, EMC-fields and corrosion |
Measurement range | High impedance cable not necessary |
Design | Easy to handle Bajonett coupling to connect digital sensors with Memosens technology and plug-head No open contacts, resistant against humidity |
Material | Cable sheath: TPE Junction box: aluminum |
Dimension | Diameter: 6.3 mm (0.25 inch) Cores: 2x2 cores, twisted pairs Length: up to approx. 100 m (328 ft) |
Process temperature | -25 to 135 °C (-13 to 277 °F) |
Process pressure | max. 50 bar/725 psi at 135°C/275°F. |
Temperature sensor | For digital sensors with inductive plug-head with and without temperature sensor |
Ex certification | ATEX II 1G Ex ia IIC T3/T4/T6 FM, CSA IS Cl.1 Div 1 Gr. A-D ATEX, NEPSI II 3G Ex nL IIC TIIS |
Ingress protection | IP68 |
Additional certifications | Also available as TÜV approved SIL version |
Measuring principle | Sensor ORP / Redox |
Application | Measuring cable for contactless, inductive, digital transmission of measurement signals. |
Installation | Inductive plug- head for digital sensors with Memosens technology and wire terminals or M12 plug to connect to the transmitter. |
Characteristic | Inductive, digital transmission of measurement signals and energy. Not influenced by moisture, EMC-fields and corrosion |
Design | Easy to handle Bajonett coupling to connect digital sensors with Memosens technology and plug-head No open contacts, resistant against humidity |
Material | Cable sheath: TPE Junction box: aluminum |
Dimension | Diameter: 6.3 mm (0.25 inch) Cores: 2x2 cores, twisted pairs Length: up to approx. 100 m (328 ft) |
Process temperature | -25 to 135 °C (-13 to 277 °F) |
Temperature sensor | For digital sensors with inductive plug-head with and without temperature sensor |
Ex certification | ATEX II 1G Ex ia IIC T3/T4/T6 FM, CSA IS Cl.1 Div 1 Gr. A-D ATEX, NEPSI II 3G Ex nL IIC TIIS |
Additional certifications | Also available as TÜV approved SIL version |
Measuring principle | Conductive |
Application | Measuring cable for contactless, inductive, digital transmission of measurement signals |
Installation | Inductive plug- head for digital sensors with Memosens technology and wire terminals or M12 plug to connect to the transmitter |
Characteristic | Inductive, digital transmission of measurement signals and energy Not influenced by moisture, EMC-fields and corrosion |
Design | Easy to handle Bajonett coupling to connect digital sensors with Memosens technology and plug-head No open contacts, resistant against humidity |
Material | Cable sheath: TPE Junction box: aluminum |
Dimension | Diameter: 6.3 mm (0.25 inch) Cores: 2x2 cores, twisted pairs Length: up to approx. 100 m (328 ft) |
Process temperature | -25 to 135 °C (-13 to 277 °F) |
Temperature sensor | For digital sensors with inductive plug-head with and without temperature sensor |
Ex certification | ATEX II 1G Ex ia IIC T3/T4/T6 FM, CSA IS Cl.1 Div 1 Gr. A-D ATEX, NEPSI II 3G Ex nL IIC TIIS |
Additional certifications | Also available as TÜV approved SIL version |
Measuring principle | Amperometric oxygen measurement |
Application | Measuring cable for contactless, inductive, digital transmission of measurement signals |
Installation | Inductive plug- head for digital sensors with Memosens technology and wire terminals or M12 plug to connect to the transmitter |
Characteristic | Inductive, digital transmission of measurement signals and energy Not influenced by moisture, EMC-fields and corrosion |
Design | Easy to handle Bajonett coupling to connect digital sensors with Memosens technology and plug-head No open contacts, resistant against humidity |
Material | Cable sheath: TPE Junction box: aluminum |
Dimension | Diameter: 6.3 mm (0.25 inch) Cores: 2x2 cores, twisted pairs Length: up to approx. 100 m (328 ft) |
Process temperature | -25 ... 135 °C (-13 ... 277 °F) |
Temperature sensor | For digital sensors with inductive plug-head with and without temperature sensor |
Ex certification | ATEX II 1G Ex ia IIC T3/T4/T6 FM, CSA IS Cl.1 Div 1 Gr. A-D ATEX, NEPSI II 3G Ex nL IIC TIIS |
Additional certifications | Also available as TÜV approved SIL version |
Measuring principle | Free chlorine |
Application | Measuring cable for contactless, inductive, digital transmission of measurement signals |
Characteristic | Inductive, digital transmission of measurement signals and energy Not influenced by moisture, EMC-fields and corrosion |
Design | Easy to handle Bajonett coupling to connect digital sensors with Memosens technology and plug-head No open contacts, resistant against humidity |
Material | Cable sheath: TPE Junction box: aluminum |
Dimension | Diameter: 6.3 mm (0.25 inch) Cores: 2x2 cores, twisted pairs Length: up to approx. 100 m (328 ft) |
Process temperature | -25 to 135 °C (-13 to 277 °F) |
Temperature sensor | For digital sensors with inductive plug-head with and without temperature sensor |
Additional certifications | Also available as TÜV approved SIL version |
Returns Policy