Endress+Hauser Digital measuring cable CYK10
Measuring principlePotentiometric
ApplicationMeasuring cable for contactless, inductive, digital transmission of measurement signals
InstallationInductive plug- head for digital sensors with Memosens technology and wire terminals or M12 plug to connect to the transmitter
CharacteristicInductive, digital transmission of measurement signals and energy
Not influenced by moisture, EMC-fields and corrosion
Measurement rangeHigh impedance cable not necessary
DesignEasy to handle Bajonett coupling to connect digital sensors with Memosens technology and plug-head
No open contacts, resistant against humidity
MaterialCable sheath: TPE
Junction box: aluminum
DimensionDiameter: 6.3 mm (0.25 inch)
Cores: 2x2 cores, twisted pairs
Length: up to approx. 100 m (328 ft)
Process temperature-25 to 135 °C (-13 to 277 °F)
Process pressuremax. 50 bar/725 psi at 135°C/275°F.
Temperature sensorFor digital sensors with inductive plug-head with and without temperature sensor
Ex certificationATEX II 1G Ex ia IIC T3/T4/T6
FM, CSA IS Cl.1 Div 1 Gr. A-D
ATEX, NEPSI II 3G Ex nL IIC
TIIS
Ingress protectionIP68
Additional certificationsAlso available as TÜV approved SIL version
Measuring principleSensor ORP / Redox
ApplicationMeasuring cable for contactless, inductive, digital transmission of measurement signals.
InstallationInductive plug- head for digital sensors with Memosens technology and wire terminals or M12 plug to connect to the transmitter.
CharacteristicInductive, digital transmission of measurement signals and energy.
Not influenced by moisture, EMC-fields and corrosion
DesignEasy to handle Bajonett coupling to connect digital sensors with Memosens technology and plug-head
No open contacts, resistant against humidity
MaterialCable sheath: TPE
Junction box: aluminum
DimensionDiameter: 6.3 mm (0.25 inch)
Cores: 2x2 cores, twisted pairs
Length: up to approx. 100 m (328 ft)
Process temperature-25 to 135 °C (-13 to 277 °F)
Temperature sensorFor digital sensors with inductive plug-head with and without temperature sensor
Ex certificationATEX II 1G Ex ia IIC T3/T4/T6
FM, CSA IS Cl.1 Div 1 Gr. A-D
ATEX, NEPSI II 3G Ex nL IIC
TIIS
Additional certificationsAlso available as TÜV approved SIL version
Measuring principleConductive
ApplicationMeasuring cable for contactless, inductive, digital transmission of measurement signals
InstallationInductive plug- head for digital sensors with Memosens technology and wire terminals or M12 plug to connect to the transmitter
CharacteristicInductive, digital transmission of measurement signals and energy
Not influenced by moisture, EMC-fields and corrosion
DesignEasy to handle Bajonett coupling to connect digital sensors with Memosens technology and plug-head
No open contacts, resistant against humidity
MaterialCable sheath: TPE
Junction box: aluminum
DimensionDiameter: 6.3 mm (0.25 inch)
Cores: 2x2 cores, twisted pairs
Length: up to approx. 100 m (328 ft)
Process temperature-25 to 135 °C (-13 to 277 °F)
Temperature sensorFor digital sensors with inductive plug-head with and without temperature sensor
Ex certificationATEX II 1G Ex ia IIC T3/T4/T6
FM, CSA IS Cl.1 Div 1 Gr. A-D
ATEX, NEPSI II 3G Ex nL IIC
TIIS
Additional certificationsAlso available as TÜV approved SIL version
Measuring principleAmperometric oxygen measurement
ApplicationMeasuring cable for contactless, inductive, digital transmission of measurement signals
InstallationInductive plug- head for digital sensors with Memosens technology and wire terminals or M12 plug to connect to the transmitter
CharacteristicInductive, digital transmission of measurement signals and energy
Not influenced by moisture, EMC-fields and corrosion
DesignEasy to handle Bajonett coupling to connect digital sensors with Memosens technology and plug-head
No open contacts, resistant against humidity
MaterialCable sheath: TPE
Junction box: aluminum
DimensionDiameter: 6.3 mm (0.25 inch)
Cores: 2x2 cores, twisted pairs
Length: up to approx. 100 m (328 ft)
Process temperature-25 ... 135 °C (-13 ... 277 °F)
Temperature sensorFor digital sensors with inductive plug-head with and without temperature sensor
Ex certificationATEX II 1G Ex ia IIC T3/T4/T6
FM, CSA IS Cl.1 Div 1 Gr. A-D
ATEX, NEPSI II 3G Ex nL IIC
TIIS
Additional certificationsAlso available as TÜV approved SIL version
Measuring principleFree chlorine
ApplicationMeasuring cable for contactless, inductive, digital transmission of measurement signals
CharacteristicInductive, digital transmission of measurement signals and energy
Not influenced by moisture, EMC-fields and corrosion
DesignEasy to handle Bajonett coupling to connect digital sensors with Memosens technology and plug-head
No open contacts, resistant against humidity
MaterialCable sheath: TPE
Junction box: aluminum
DimensionDiameter: 6.3 mm (0.25 inch)
Cores: 2x2 cores, twisted pairs
Length: up to approx. 100 m (328 ft)
Process temperature-25 to 135 °C (-13 to 277 °F)
Temperature sensorFor digital sensors with inductive plug-head with and without temperature sensor
Additional certificationsAlso available as TÜV approved SIL version