Endress+Hauser
Endress+Hauser Digital combined pH/ORP sensor Memosens CPS96E
REQUEST A QUOTE
Measurement range | ORP: –1 500 to 1 500 mV pH: 0 to 14 |
---|---|
Process temperature | 0 to 110 °C (32 to 230 °F) |
Process pressure | 0.8 to 14 bar (11.6 to 203 psi) absolute |
Measuring principle | Potentiometric |
Application | pH / ORP sensor for heavily contaminated media and suspended solids • Chemical processes • Pulp and paper industry • Flue gas cleaning • Contaminated media: • Solids • Emulsions • Precipitation reactions |
Characteristic | Gel pH/ORP electrode with open aperture and double gel reference with ion trap for chemical applications |
Measurement range | ORP: –1 500 to 1 500 mV pH: 0 to 14 |
Measuring principle | Pt-disc as additional ORP element rH measurement and control of the reference impedance |
Design | All shaft lengths with temperature sensor Advanced gel technology Hydrolysis stable gel |
Material | Sensor shaft: Glass to suit process pH membrane glass: Type B Metal lead: Ag/AgCl ORP measuring element: Platinum O-ring: FKM Process coupling: PPS fiber-glass reinforced Nameplate: Ceramic metal oxide |
Dimension | Diameter: 12 mm (0.46 inch) Shaft lengths: 120, 225, 360 and 425 mm (4.68, 8.77, 14.04 and 16.57 inch) |
Process temperature | 0 to 110 °C (32 to 230 °F) |
Process pressure | 0.8 to 14 bar (11.6 to 203 psi) absolute |
Temperature sensor | NTC 30k |
Ex certification | With ATEX, IECEx, CSA C/US, NEPSI, Japan Ex and INMETRO approvals for use in hazardous areas Zone 0, Zone 1 and Zone 2 |
Connection | Inductive, digital connection head with Memosens 2.0 technology |
Ingress protection | IP68 |
Measuring principle | Sensor ORP / Redox |
Application | pH / ORP sensor for heavily contaminated media and suspended solids • Chemical processes • Pulp and paper industry • Flue gas cleaning • Contaminated media: • Solids • Emulsions • Precipitation reactions |
Characteristic | Gel pH/ORP electrode with open aperture and double gel reference with ion trap for chemical applications |
Measurement range | ORP: –1 500 to 1 500 mV pH: 0 to 14 |
Measuring principle | Pt-disc as additional ORP element rH measurement and control of the reference impedance |
Design | All shaft lengths with temperature sensor Advanced gel technology Hydrolysis stable gel |
Material | Sensor shaft: Glass to suit process pH membrane glass: Type B Metal lead: Ag/AgCl ORP measuring element: Platinum O-ring: FKM Process coupling: PPS fiber-glass reinforced Nameplate: Ceramic metal oxide |
Dimension | Diameter: 12 mm (0.46 inch) Shaft lengths: 120, 225, 360 and 425 mm (4.68, 8.77, 14.04 and 16.57 inch) |
Process temperature | 0 to 110 °C (32 to 230 °F) |
Process pressure | 0.8 to 14 bar (11.6 to 203 psi) absolute |
Temperature sensor | NTC 30k |
Ex certification | With ATEX, IECEx, CSA C/US, NEPSI, Japan Ex and INMETRO approvals for use in hazardous areas Zone 0, Zone 1 and Zone 2 |
Connection | Inductive, digital connection head with Memosens 2.0 technology |
Ingress protection | IP68 |
Returns Policy