Endress+Hauser Digital combined pH/ORP sensor Memosens CPS96E

Write a Review

REQUEST A QUOTE

Endress+Hauser Digital combined pH/ORP sensor Memosens CPS96E
Measurement rangeORP: –1 500 to 1 500 mV
pH: 0 to 14
Process temperature0 to 110 °C (32 to 230 °F)
Process pressure0.8 to 14 bar (11.6 to 203 psi) absolute
Measuring principlePotentiometric
ApplicationpH / ORP sensor for heavily contaminated media
and suspended solids
• Chemical processes
• Pulp and paper industry
• Flue gas cleaning
• Contaminated media:
• Solids
• Emulsions
• Precipitation reactions
CharacteristicGel pH/ORP electrode with open aperture and double gel reference with ion trap for chemical applications
Measurement rangeORP: –1 500 to 1 500 mV
pH: 0 to 14
Measuring principlePt-disc as additional ORP element
rH measurement and control of the reference impedance
DesignAll shaft lengths with temperature sensor
Advanced gel technology
Hydrolysis stable gel
MaterialSensor shaft: Glass to suit process
pH membrane glass: Type B
Metal lead: Ag/AgCl
ORP measuring element: Platinum
O-ring: FKM
Process coupling: PPS fiber-glass reinforced
Nameplate: Ceramic metal oxide
DimensionDiameter: 12 mm (0.46 inch)
Shaft lengths: 120, 225, 360 and 425 mm
(4.68, 8.77, 14.04 and 16.57 inch)
Process temperature0 to 110 °C (32 to 230 °F)
Process pressure0.8 to 14 bar (11.6 to 203 psi) absolute
Temperature sensorNTC 30k
Ex certificationWith ATEX, IECEx, CSA C/US, NEPSI, Japan Ex and INMETRO approvals for use in
hazardous areas Zone 0, Zone 1 and Zone 2
ConnectionInductive, digital connection head with Memosens 2.0 technology
Ingress protectionIP68
Measuring principleSensor ORP / Redox
ApplicationpH / ORP sensor for heavily contaminated media
and suspended solids
• Chemical processes
• Pulp and paper industry
• Flue gas cleaning
• Contaminated media:
• Solids
• Emulsions
• Precipitation reactions
CharacteristicGel pH/ORP electrode with open aperture and double gel reference with ion trap for chemical applications
Measurement rangeORP: –1 500 to 1 500 mV
pH: 0 to 14
Measuring principlePt-disc as additional ORP element
rH measurement and control of the reference impedance
DesignAll shaft lengths with temperature sensor
Advanced gel technology
Hydrolysis stable gel
MaterialSensor shaft: Glass to suit process
pH membrane glass: Type B
Metal lead: Ag/AgCl
ORP measuring element: Platinum
O-ring: FKM
Process coupling: PPS fiber-glass reinforced
Nameplate: Ceramic metal oxide
DimensionDiameter: 12 mm (0.46 inch)
Shaft lengths: 120, 225, 360 and 425 mm
(4.68, 8.77, 14.04 and 16.57 inch)
Process temperature0 to 110 °C (32 to 230 °F)
Process pressure0.8 to 14 bar (11.6 to 203 psi) absolute
Temperature sensorNTC 30k
Ex certificationWith ATEX, IECEx, CSA C/US, NEPSI, Japan Ex and INMETRO approvals for use in
hazardous areas Zone 0, Zone 1 and Zone 2
ConnectionInductive, digital connection head with Memosens 2.0 technology
Ingress protectionIP68
Returns Policy

Related Products

Top