Endress+Hauser
Endress+Hauser Digital combined pH/ORP sensor Memosens CPS16E
REQUEST A QUOTE
Measurement range | ORP: –1 500 … 1 500 mV Application: A • pH: 1 to 12 Application B • pH: 0 to 14 |
---|---|
Process temperature | Application A: –15 to 80 °C (5 to 176 °F) Application B: 0 to 135 °C (32 to 275 °F) |
Process pressure | 0.8 to 17 bar (11.6 to 246,5 psi) absolute |
Measuring principle | Potentiometric |
Application | Long-term monitoring and limit control in processes with stable process conditions • Chemical processes • Pulp and paper industry • Waste incinerators and gas scrubbers • Mining • Wastewater |
Characteristic | Combination of pH and ORP electrode for standard applications in process technology and environmental engineering Poison-resistant reference with ion trap |
Measurement range | ORP: –1 500 to 1 500 mV Application A • pH: 1 to 12 Application B • pH: 0 to 14 |
Measuring principle | Gel compact electrode with PTFE ring-junction and with ion trap Pt-disc as additional ORP element rH measurement and control of the reference impedance |
Design | All shaft lengths with temperature sensor Advanced gel technology |
Material | Sensor shaft: Glass to suit process pH membrane glass: Type A, B Metal lead: Ag/AgCl Open aperture: PFTE junction, sterilizable ORP measuring element: Platinum O-ring: FKM Process coupling: PPS fiber-glass reinforced Nameplate: Ceramic metal oxide |
Dimension | Diameter: 12 mm (0.47 inch) Shaft lengths: 120, 225 and 360 mm (4.72, 8.86, 14.17 and 16.73 inch) |
Process temperature | Application A: –15 to 80 °C (5 to 176 °F) Application B: 0 to 135 °C (32 to 275 °F) |
Process pressure | 0.8 to 17 bar (11.6 to 246,5 psi) absolute |
Temperature sensor | NTC 30k |
Ex certification | With ATEX, IECEx, CSA C/US, NEPSI, Japan Ex and INMETRO approvals for use in hazardous areas Zone 0, Zone 1 and Zone 2 |
Connection | Inductive, digital connection head with Memosens 2.0 technology |
Ingress protection | IP68 |
Measuring principle | Sensor ORP / Redox |
Application | Long-term monitoring and limit control in processes with stable process conditions Chemical processes • Pulp and paper industry • Waste incinerators and gas scrubbers • Mining • Wastewater |
Characteristic | Combination of pH and ORP electrode for standard applications in process technology and environmental engineering Poison-resistant reference with ion trap |
Measurement range | ORP: –1 500 … 1 500 mV Application: A • pH: 1 to 12 Application B • pH: 0 to 14 |
Measuring principle | Gel compact electrode with PTFE ring-junction with ion trap Pt-disc as additional ORP element rH measurement and control of the reference impedance |
Design | All shaft lengths with temperature sensor Advanced gel technology |
Material | Sensor shaft: Glass to suit process pH membrane glass: Type A, B Metal lead: Ag/AgCl Open aperture: PFTE junction, sterilizable ORP measuring element: Platinum O-ring: FKM Process coupling: PPS fiber-glass reinforced Nameplate: Ceramic metal oxide |
Dimension | Diameter: 12 mm (0.47 inch) Shaft lengths: 120, 225 and 360 mm (4.72, 8.86, 14.17 and 16.73 inch) |
Process temperature | Application A: –15 to 80 °C (5 to 176 °F) Application B: 0 to 135 °C (32 to 275 °F) |
Process pressure | 0.8 to 17 bar (11.6 to 246,5 psi) absolute |
Temperature sensor | NTK 30k |
Ex certification | With ATEX, IECEx, CSA C/US, NEPSI, Japan Ex and INMETRO approvals for use in hazardous areas Zone 0, Zone 1 and Zone 2 |
Connection | Inductive, digital connection head with Memosens 2.0 technology |
Ingress protection | IP68 |
Returns Policy