Endress+Hauser Differential pressure Deltabar PMD55

Write a Review

REQUEST A QUOTE

Endress+Hauser Differential pressure Deltabar PMD55
Accuracy0,1%
"PLATINUM" 0,075%
Max. measurement error0,1%
"PLATINUM" 0,075%
Process temperature-40 °C...85 °C
(-40 °F...185 °F)
Medium temperature rangeTemperature gradient from pressure piping
Pressure measuring range10mbar...40bar
(0.15...580psi)
Process pressure / max. overpressure limit160 bar
Main wetted parts316L
Max. process pressure10 mbar...40 bar
(0.15...580 psi)
Material process membrane316L, AlloyC,
Measuring cell10 mbar...40 bar
(0.15...580 psi)
Measuring principleDifferential pressure
Product headlineDigital transmitter with metallic measuring diaphragms
Compact size
Modular transmitter
Long-term stability


Max. measurement error0,1%
"PLATINUM" 0,075%
Max. process pressure10mbar...40bar
(0.15...580psi)
Medium temperature rangeTemperature gradient from pressure piping
Display/OperationOption
Outputs4...20mA HART
Digital communicationHART
Hazardous area approvalsATEX, FM, CSA, IECEx, INMETRO, NEPSI, TIIS
Functional safetySIL
Material certificatesNACE MR0103
NACE MR0175
EN10204-3.1
Measuring principleDifferential pressure
CharacteristicDigital transmitter with metallic measuring diaphragms
Compact size
Modular transmitter
Long-term stability
Supply voltage4...20 mA HART
11,5...45V DC (Non Ex):
Ex ia: 11,5...30V DC
PROFIBUS PA:
9...32 V DC (Non Ex)
FOUNDATION Fieldbus:
9...32 V DC (Non Ex)
Reference AccuracyStandard 0.1%
Platinum 0.075%
Long term stability0.05% of URL/ year
0.13% of URL/ 5 years
0.23% of URL/ 10 years
Process temperature-40°C...+85°C
(-40°F...+185°F)
Ambient temperature-40°C...+85°C
(-40°F...+185°F)
Measuring cell10 mbar...40 bar
(0.15...580 psi)
Smallest calibratable span10 mbar (0.15 psi)
Max. Turn down20:1
Max. overpressure limiton one side:
160 bar
(2300 psi)
Process connection1/4-18 NPT
Material process membrane316L, AlloyC,
Material gasketViton, PTFE, EPDM, NBR
Fill fluidSilicone oil
Inert oil
Material housingDie-cast aluminum
Communication4...20 mA HART
PROFIBUS PA
FOUNDATION Fieldbus
Certificates / ApprovalsATEX, FM, CSA, CSA C/US, IEC Ex, INMETRO, NEPSI, UK Ex
Safety approvalsSIL
Design approvalsNACE MR0175
EN10204-3.1
SuccessorPMD55B
Measuring principleDifferential pressure
Product headlineDigital transmitter with metallic measuring diaphragms
Compact size
Modular transmitter
Long-term stability
Max. measurement error0,1%
"PLATINUM" 0,075%
Max. process pressure10mbar...40bar
(0.15...580psi)
Medium temperature rangeTemperature gradient from pressure piping
Display/OperationOption
Outputs4...20mA HART
Digital communicationHART
Hazardous area approvalsATEX, FM, CSA, IECEx, INMETRO, NEPSI, TIIS
Functional safetySIL
Material certificatesNACE MR0103
NACE MR0175
EN10204-3.1
Measuring principleDifferential pressure
Characteristic / ApplicationDigital transmitter with metallic measuring diaphragms
Compact size
Modular transmitter
Long-term stability
Supply / Communication4...20mA HART:
11,5...45V DC
Ex ia: 11,5...30V DC
Accuracy0,1%
"PLATINUM" 0,075%
Long term stability0,05% of URL/year
0,125% of URL/5 years
Ambient temperature-40°C...85°C
(-40°F...185°F)
Process temperature-40 °C...85 °C
(-40 °F...185 °F)
Process pressure / max. overpressure limit160 bar
Pressure measuring range10mbar...40bar
(0.15...580psi)
Main wetted parts316L
Process connection1/4-18 NPT
Communication4...20mA HART
PROFIBUS PA
FOUNDATION Fieldbus
Certificates / ApprovalsATEX, FM, CSA, CSA C/US, IEC Ex, INMETRO, NEPSI
Safety approvalsSIL
Design approvalsEN 10204-3.1
NACE MR0175, MR0103
AD2000
Options4-line digital display
Aluminium housing
SuccessorPMD55B
Application limitsMeasuring cell:
Metal welded
Measuring principleDifferential pressure
Product headlineDigital transmitter with metallic measuring diaphragms
Compact size
Modular transmitter
Long-term stability
Max. measurement error0,1%
"PLATINUM" 0,075%
Max. process pressure10 mbar...40 bar
(0.15...580 psi)
Medium temperature rangeTemperature gradient from pressure piping
Display/OperationOption
Outputs4...20mA HART
Digital communicationHART
Hazardous area approvalsATEX, FM, CSA, IECEx, INMETRO, NEPSI, TIIS
Functional safetySIL
Material certificatesNACE MR0103
NACE MR0175
EN10204-3.1
Returns Policy

Related Products

Top